11
C.2 lighting Procedures (Continued.)
ManUal IGnITIon
Nieco Corporation - Model JF64-3G
1. Allow the broiler
to run free of
any product for
10 minutes.
This will burn
the chain clean.
2. Close the main
gas valve and
allow the
broiler to
without gas for
10 minutes.
3. Turn off the
Main Power
switch
.
4. Wait for the
broiler to
cool.
C.3 shutdown Procedures
PlanneD sHUTDoWn
2. Close the
MaIn Gas
ValVe
Valve is closed
when it is perpendi-
cular to pipe.
eMeRGenCY sHUTDoWn
1. Turn off the
MaIn PoWeR
sWITCH.
Your Nieco Automatic Broiler is designed to automatically stop gas flow to the broiler in the event of power failure, gas
pressure loss or any other related incident. No attempt to operate this appliance should be made in the event of a power
failure.
CaUTIon
In a prominent location, post
instructions to be followed in the
event the user smells gas. This
information shall be obtained by
consulting your local gas supplier.
CaUTIon
foR YoUR safeTY: Do not store
or use gasoline or other flammable
vapors or liquids in the vicinity of
this or any other appliance.
CaUTIon
foR YoUR safeTY: In the event of
a prolonged power failure, no
attempt should be made to operate
this appliance.
1. Remove the return awning. Turn the
MaIn PoWeR
sWITCH
on. Hold a lighter/match to the upper burner on
the discharge end until the burner lights. Once the first
burner is lit, verify that all burners have ignited.