Nieco 922G Скачать руководство пользователя страница 6

6

Note: This appliance and its individual shutoff valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressures in excess of 1/2 psig
(3.45 kPa).

Note: This appliance must be isolated from the gas supply piping system by closing its individual
manual shutoff valve during any pressure testing of the gas supply piping system at test pres-
sures equal to or less than 1/2 psig (3.45 kPa).

In Canada, installation shall be in accordance with CAN/CGA-B149.1 Natural Gas or CAN/CGA-B149.2
Propane Gas, and local codes where applicable.

By public initiative, the State of California has adopted legislation (Proposition 65) which requires manu-
facturers of many types of products, including gas appliances, to warn consumers of their products that
contain chemicals or produce substances listed by the State of California to either cause cancer, birth
defects, or other reproductive harm.

WARNING: If not installed, operated, and maintained in accordance with the manufacturer's
instructions, this product could expose you to substances in fuel, or from fuel combustion which
can cause cancer, birth defects, or other reproductive harm.

ELECTRICAL CONNECTION
Power requirements are stated on the unit nameplate and must be connected accordingly. Before starting
broiler, tighten all electrical connections in control box. An electrical diagram is located inside the control
box.

Note: This appliance must be electrically grounded in accordance with local codes or in the
absence of local codes, the National Electrical Code, ANSI/NFPA No. 70-1990. In Canada, in
accordance with the Canadian Electrical Code CSA 22.2, or local codes.

WARNING: This appliance should be connected with a four-pronged grounding plug for
your protection against shock hazard. Be sure to plug directly into a properly grounded
four-prong receptacle. Do not cut or remove grounding prong from plug.

Note: This appliance cannot be safely operated in the event of a power failure. No attempt
should be made to operate during a power failure. Disconnect power supply before servicing.

PRE-OPERATION CHECK
Be sure that all parts are installed in the proper location. Refer to OPERATION section for lighting proce-
dure. Start broiler and test for proper operation.

Содержание 922G

Страница 1: ...ntact your Nieco Authorized Dealer In a prominent location post instructions to be followed in the event the user smells gas This information shall be obtained by consulting your local gas supplier FO...

Страница 2: ......

Страница 3: ...Connectors and Restraining Device C Operation 8 Controls and Indicators Gas System Controls Step by Step Lighting Procedure Shutdown Procedure Automatic Temperature Control D Parts and Location 11 Exp...

Страница 4: ...section The broiler is divided into two sections The top section uses a conveyor belt system to pass food through the cook zone where infrared convection and conduction heat is used to cook the produc...

Страница 5: ...earance from combustible and non combustible construction is 6 152MM from the back and 6 152MM from the front of the machine Keep appliance area free from combustibles To facilitate disassembly and se...

Страница 6: ...ons this product could expose you to substances in fuel or from fuel combustion which can cause cancer birth defects or other reproductive harm ELECTRICAL CONNECTION Power requirements are stated on t...

Страница 7: ...de of heavy duty steel cable with a strong scissor hood 2 at one end and an equally strong spring hook 3 at the other Cotter pin 4 is supplied to secure the installation For safety in the kitchen area...

Страница 8: ...egulator Valve is open when in line with pipe Controls the gas pressure in High Gas mode 3 High Gas Solenoid 1 2 3 4 5 Gas Pressure Gauge Pushbutton Gas Valve Red 5 Amp Fuse Pilot Ignitor Red Meat Hol...

Страница 9: ...While holding in the Red Button push the Ignitor button on the front of the control box After the pilot lights hold the Red Valve in for 30 seconds to allow the thermocouple to heat When you release...

Страница 10: ...600 F 2 Turn on the Main Power Switch 3 Turn on the Motor Power Switch 4 Light the broiler following the procedure in this manual 5 The broiler should be in high gas mode at this time Amber light on...

Страница 11: ...11 D PARTS AND LOCATION Model 952 Gas Feed End View Model 952 Gas Right Side View...

Страница 12: ...12 Model 952 Gas Left Side View Model 932 Gas Feed End View P N 8455...

Страница 13: ...13 Model 932 Gas Right Side View Model 932 Gas Left Side View P N 8455...

Страница 14: ...14 Model 922 Gas Feed End View Model 922 Gas Right Side View...

Страница 15: ...15 Model 922 Gas Left Side View...

Страница 16: ...disassemble 2 Remove the Side Panels by 2 3 lifting up and off Wipe clean with a degreaser FROM THE FRONT OF THE BROILER 3 Remove the Patty Feeder by lifting up and out Clean daily using soap and wat...

Страница 17: ...F THE BROILER 11 Remove the awning by lifting up 11 12 and off Clean using soap and water 12 Remove the Return Pan by lifting off the pegs and sliding out Clean and sanitize the pan and the Teflon She...

Страница 18: ...AT THE FIRST SIGN OF BREAKAGE DO NOT SOAK OR SUBMERGE THE BURNERS IN WATER WATER WILL DAMAGE THE GASKET SEAL CAUS ING IMPROPER BURNER PERFORMANCE 17 Wipe off the frame and other internal parts of the...

Страница 19: ...face Be sure to re assemble in the same way 1 Run belt until the Master Link is 1 near the front idler shaft 2 Lift shaft and Teflon Blocks up 2 3 and slide the blocks out 3 Unhook the Master Link To...

Страница 20: ...stored position and remove a link from the conveyor belt BROIL BELT PROBLEMS Interference with stripper blade The most common belt problem to be expected is the physical interference of the belt with...

Страница 21: ...out 3 Electrical supply interruption 4 See 2 and 3 above 1 Orifices dirty 2 Gas pressure too low 3 Main gas valve partially closed 4 Gas line partially blocked 5 Pressure regulator defective 6 Burner...

Страница 22: ...ct temperature too low 3 Product too lean 4 Exhaust fan pulling too much air 5 Exhaust hood too low 6 Air vent blowing on broiler 7 Heat reflectors inside broiler not installed or installed improperly...

Страница 23: ...ooking product 2 Product fat content too high 3 Gas pressure too high 1 Product fat content too high 2 Product grind too coarse 3 Product too lean sticking to belt 4 Product too thin 5 Stripper blade...

Страница 24: ...Connection 208 240Y120V 1 50 60Hz 11A Avg KW Hr Consumption 1 1 Gas Consumption 75 000 96 000 BTU Hr 3 W C Nat or 8 W C L P Low Gas 5 W C Nat or 11 W C L P High Gas Weight LBS KG Approximate 475 215...

Страница 25: ...on 208 240Y120V 1 50 60Hz 11A Avg KW Hr Consumption 1 1 Gas Consumption 54 000 70 000 BTU Hr 3 W C Nat or 8 W C L P Low Gas 5 W C Nat or 11 W C L P High Gas Weight LBS KG Approximate 375 170 Exhaust C...

Страница 26: ...on 208 240Y120V 1 50 60Hz 8A Avg KW Hr Consumption 8 Gas Consumption 33 000 44 000 BTU Hr 3 W C Nat or 8 W C L P Low Gas 5 W C Nat or 11 W C L P High Gas Weight LBS KG Approximate 250 113 Exhaust CFM...

Страница 27: ...27 J WIRING DIAGRAM Models 952 932G Domestic U S A...

Страница 28: ...28 Models 952 932G International Export Models...

Страница 29: ...29 Model 922G Domestic U S A...

Страница 30: ...30 Model 922G International Export Models...

Страница 31: ......

Страница 32: ...Nieco Corporation 15 Guittard Rd Burlingame CA 94010 415 697 7335 Fax 415 697 3014 Reorder 9999 99111 10 97 Printed in the USA...