6
Note: This appliance and its individual shutoff valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressures in excess of 1/2 psig
(3.45 kPa).
Note: This appliance must be isolated from the gas supply piping system by closing its individual
manual shutoff valve during any pressure testing of the gas supply piping system at test pres-
sures equal to or less than 1/2 psig (3.45 kPa).
In Canada, installation shall be in accordance with CAN/CGA-B149.1 Natural Gas or CAN/CGA-B149.2
Propane Gas, and local codes where applicable.
By public initiative, the State of California has adopted legislation (Proposition 65) which requires manu-
facturers of many types of products, including gas appliances, to warn consumers of their products that
contain chemicals or produce substances listed by the State of California to either cause cancer, birth
defects, or other reproductive harm.
WARNING: If not installed, operated, and maintained in accordance with the manufacturer's
instructions, this product could expose you to substances in fuel, or from fuel combustion which
can cause cancer, birth defects, or other reproductive harm.
ELECTRICAL CONNECTION
Power requirements are stated on the unit nameplate and must be connected accordingly. Before starting
broiler, tighten all electrical connections in control box. An electrical diagram is located inside the control
box.
Note: This appliance must be electrically grounded in accordance with local codes or in the
absence of local codes, the National Electrical Code, ANSI/NFPA No. 70-1990. In Canada, in
accordance with the Canadian Electrical Code CSA 22.2, or local codes.
WARNING: This appliance should be connected with a four-pronged grounding plug for
your protection against shock hazard. Be sure to plug directly into a properly grounded
four-prong receptacle. Do not cut or remove grounding prong from plug.
Note: This appliance cannot be safely operated in the event of a power failure. No attempt
should be made to operate during a power failure. Disconnect power supply before servicing.
PRE-OPERATION CHECK
Be sure that all parts are installed in the proper location. Refer to OPERATION section for lighting proce-
dure. Start broiler and test for proper operation.
Содержание 922G
Страница 2: ......
Страница 11: ...11 D PARTS AND LOCATION Model 952 Gas Feed End View Model 952 Gas Right Side View...
Страница 12: ...12 Model 952 Gas Left Side View Model 932 Gas Feed End View P N 8455...
Страница 13: ...13 Model 932 Gas Right Side View Model 932 Gas Left Side View P N 8455...
Страница 14: ...14 Model 922 Gas Feed End View Model 922 Gas Right Side View...
Страница 15: ...15 Model 922 Gas Left Side View...
Страница 27: ...27 J WIRING DIAGRAM Models 952 932G Domestic U S A...
Страница 28: ...28 Models 952 932G International Export Models...
Страница 29: ...29 Model 922G Domestic U S A...
Страница 30: ...30 Model 922G International Export Models...
Страница 31: ......