background image

18

Model 522 Gas - Left Side View

REGISTERED NIECO CORP., 1994

DWG8260A

12-14-94

P/N 4073

P/N 4424

AWNING

P/N 9487

P/N 9495

ADJUSTABLE LEG

P/N 0003-01

P/N 9486

P/N 8036

13" ROD BELT

P/N 6035

P/N 8037

P/N 6683

P/N 9484

BELT SCRAPER

RETURN PAN

TEFLON

HOLDING

STRIP

P/N 9496

P/N 9493

P/N 9497

P/N 6160

PROBE

PLATEN

LOWER BURNER

REFLECTOR

UPPER BURNER

FRONT REFLECTOR

UPPER BURNER

GREASE PAN

LOWER BURNER

TEFLON SHEET

STRIPPER BLADE

SHIELD

P/N 8214-01

REVERBERATOR

P/N 8214

Содержание 522G

Страница 1: ...r functions Contact your Nieco Authorized Dealer In a prominent location post instructions to be followed in the event the user smells gas This information shall be obtained by consulting your local g...

Страница 2: ...Connectors and Restraining Device C Operation 7 Controls and Indicators Gas System Controls Step by Step Lighting Procedure Shutdown Procedure Automatic Temperature Control D Parts and Location 10 Exp...

Страница 3: ...section The broiler is divided into two sections The top section uses a conveyor belt system to pass food through the cook zone where infrared convection and conduction heat is used to cook the produc...

Страница 4: ...le construction is 6 152MM from the back and 6 152MM from the front of the machine Keep appliance area free from combustibles To facilitate disassembly and service of the unit a minimum of 24 610MM sh...

Страница 5: ...this product could expose you to substances in fuel or from fuel combustion which can cause cancer birth defects or other reproductive harm ELECTRICAL CONNECTION Power requirements are stated on the...

Страница 6: ...de of heavy duty steel cable with a strong scissor hood 2 at one end and an equally strong spring hook 3 at the other Cotter pin 4 is supplied to secure the installation For safety in the kitchen area...

Страница 7: ...egulator Valve is open when in line with pipe Controls the gas pressure in High Gas mode 3 High Gas Solenoid 1 2 3 4 5 Gas Pressure Gauge Pushbutton Gas Valve Red 5 Amp Fuse Pilot Igniter Red Meat Hol...

Страница 8: ...While holding in the Red Button push the Igniter button on the front of the control box After the pilot lights hold the Red Valve in for 30 seconds to allow the thermocouple to heat When you release...

Страница 9: ...he ATC control knob to 600 F 2 Turn on the Main Power Switch 3 Turn on the Motor Power Switch 4 Light the broiler following the procedure in this manual 5 The broiler should be in high gas mode at thi...

Страница 10: ...10 D PARTS AND LOCATION Model 732 735 Gas Feed End View...

Страница 11: ...11 Model 732 735 Gas Right Side View...

Страница 12: ...12 Model 732 735 Gas Left Side View...

Страница 13: ...2 RED LIGHT P N 4100 TEMPERATURE CONTROL 7 07 95 P N 4426 DWG8261 GREASE BOX P N 9465 P N 9466 P N 4602 P N 4601 P N 4094 P N 2122 GREASE BOX INSERT 5 AMP FUSE FUSE HOLDER POTENTIOMETER P N 4014 BREAK...

Страница 14: ...N 2035 LP P N 2003 B P N 2021 B GAS PRESSURE REGULATOR 2 P N 2025 A REGULATOR MOTOR P N 4437 SPROCKET 32T P N 6039 DRIVE CHAIN P N 6027 SPROCKET 8T P N 6004 P N 2183 LP P N 4144 P N 4145 P N 2178 BUR...

Страница 15: ...15 Model 532 535 Gas Left Side View...

Страница 16: ...MBER LIGHT P N 4222 P N 4071 P24DC CONTROL TEMPERATURE PLATEN SPARK IGNITOR P N 4181 08 P N 4099 ON OFF SWITCH RED LIGHT P N 4100 5 AMP FUSE P N 4601 P N 4602 FUSE HOLDER GAS VALVE P N 2122 RED PUSHBU...

Страница 17: ...SPROCKET 8T P N 6004 P N 2183 LP REGISTERED NIECO CORP 1995 7 06 95 AUTOMATIC TEMPERATURE CONTROL TEFLON BEARING 4 P N 6066 P N 2178 BURNER 2 PILOT P N 2065 NAT P N 2068 LP ELECTRODE P N 4182 TEMPERA...

Страница 18: ...EG P N 0003 01 P N 9486 P N 8036 13 ROD BELT P N 6035 P N 8037 P N 6683 P N 9484 BELT SCRAPER RETURN PAN TEFLON HOLDING STRIP P N 9496 P N 9493 P N 9497 P N 6160 PROBE PLATEN LOWER BURNER REFLECTOR UP...

Страница 19: ...disassemble 2 Remove the Side Panels by 2 3 lifting up and off Wipe clean with a degreaser FROM THE FRONT OF THE BROILER 3 Remove the Patty Feeder by lifting up and out Clean daily using soap and wat...

Страница 20: ...F THE BROILER 11 Remove the awning by lifting up 11 12 and off Clean using soap and water 12 Remove the Return Pan by lifting off the pegs and sliding out Clean and sanitize the pan and the Teflon She...

Страница 21: ...not immerse the burners in water Water will damage the gasket and may cause improper burner performance The outside of the burner box can be wiped clean with a damp cloth and soap 17 Wipe off the fra...

Страница 22: ...ce Be sure to re assemble in the same way 1 Run belt until the Master Link is 1 near the front idler shaft 2 Lift shaft and Teflon Blocks up 2 3 and slide the blocks out 3 Unhook the Master Link To re...

Страница 23: ...stored position and remove a link from the conveyor belt BROIL BELT PROBLEMS Interference with stripper blade The most common belt problem to be expected is the physical interference of the belt with...

Страница 24: ...out 3 Electrical supply interruption 4 See 2 and 3 above 1 Orifices dirty 2 Gas pressure too low 3 Main gas valve partially closed 4 Gas line partially blocked 5 Pressure regulator defective 6 Burner...

Страница 25: ...ct temperature too low 3 Product too lean 4 Exhaust fan pulling too much air 5 Exhaust hood too low 6 Air vent blowing on broiler 7 Heat reflectors inside broiler not installed or installed improperly...

Страница 26: ...ooking product 2 Product fat content too high 3 Gas pressure too high 1 Product fat content too high 2 Product grind too coarse 3 Product too lean sticking to belt 4 Product too thin 5 Stripper blade...

Страница 27: ...REQUIREMENTS Energy Gas Model Gas Connection 3 4 N P T Electrical Connection 208 120V 1 50 60Hz 10 5A 240 120V 1 50 60Hz 12A Avg KW Hr Consumption 2 2 Gas Consumption 75 000 96 000 BTU Hr 3 W C Nat or...

Страница 28: ...EMENTS Energy Gas Model Gas Connection 1 2 N P T Electrical Connection 208Y120V 1 50 60Hz 9 8A 240Y120V 1 50 60Hz 10 4A Avg KW Hr Consumption 1 4 Gas Consumption 49 000 63 000 BTU Hr 3 W C Nat or 8 W...

Страница 29: ...REMENTS Energy Gas Model Gas Connection 1 2 N P T Electrical Connection 208Y120V 1 50 60Hz 6 5A 240Y120V 1 50 60Hz 7 5A Avg KW Hr Consumption 9 Gas Consumption 33 000 44 000 BTU Hr 3 W C Nat or 8 W C...

Страница 30: ...30 J WIRING DIAGRAM Models 732 735 532 535G Domestic U S A...

Страница 31: ...31 Models 732 735 532 535G International Export Models...

Страница 32: ...32 Model 522G Domestic U S A...

Страница 33: ...33 Model 522G International Export Models...

Страница 34: ...Nieco Corporation 15 Guittard Rd Burlingame CA 94010 650 697 7335 Fax 650 697 3014 Reorder 9999 99102 12 99 e mail nieco nieco com Printed in the USA...

Отзывы: