LCD DISPLAY
Main Data Display
•Flash rate value will be displayed in internal flashing or Exter-
nal trigger mode.
•Display will indicate “P” or “LCD” (in ON/OFF setting of LCD
backlight) in *Parameter setting mode.
*For details about Parameter setting mode, please refer to Pa-
rameter setting mode.
Sub Data Display
Internal Mode
•Phase Shift will indicate degrees of phase shift in internal flash-
ing mode. To change the degrees of phase shift, press + or -
keys. The display will reflect the cumulative angle of phase shift.
•The flash duration time will be displayed when the RATIO key
is pressed. The flash duration time can then be increased or
decreased with the dial from 0 to 2.5 (0~2.5°) degrees.
External Mode
• In external trigger mode, the display will show the settings of
delay time. For details about changing these settings, please
see external trigger mode section.
FUNCTION INSTRUCTIONS
Mode Selection - To switch between INTERNAL, EXTERNAL and
PARAMETER menu, press and release the MODE key. For details
about Parameter setting mode, please refer to Parameter setting
menu section.
Internal Flashing Mode
Flash Rate (Frequency Setting) in Internal Mode -
You can set the flash rate by turning the dial in the center of the
unit. To increase the flash rate, turn the dial in the clockwise direc-
tion. To decrease the flash rate, turn the dial in the counter-clock-
wise direction. For small adjustments, turn the dial slowly. For
quick adjustments, rotate the dial quickly. The flash rate range
and resolution will be different according to the selected measur-
ing range.
One function of a stroboscope is to provide a “stopped” image
of a rotating target when the flash rate of the stroboscope has
matched the rotational speed of the target object. The strobo-
scope will show a single image when the flash rate is set to a
lesser multiple of the true RPM (1/2,1/3,etc.) When the flash rate
is increased to a higher multiple (2,3,etc.), multiple images will
appear. To find the true RPM of the target object, reduce the flash
rate to a lower multiple until only one image appears.
2
Parameter
Icons
Sub
Data Display
Main
Data
Display
Units
INSTALLATION
Mounting
The control box is easily mounted to a magnetic surface with its
included magnetic bracket. Pull off bracket from back of control
box and mount through screw/bolt holes to surface. Then attach
control box to magnetic mounting bracket.The LED array may be
mounted with its mount flange located on each end. 6 mm holes
are on the flanges. For additional mounting hardware to aid array
mounting the MK-320 mounting kit provides brackets that easily
connect to the array’s flanges.
Connections
Connect power cable to power connection on underside of array.
Connect control box to array with provided 5 pin connecrion ca-
ble. Note: Attach cable to bottom left side connector (5 pin) on
control enclosure.
M-12 3 pin connector on bottom right side of control enclosure is
input control signal connection for external control.