20
ASSEMBLY AND COMMISSIONING RECOMMENDATIONS
LSHRM - FLSHRM - PLSHRM - Permanent Magnet Assisted Reluctance motors
5411 en - 2019.04 / b
• Tightening torque (N m) for the terminal block nuts
Terminal M6
M8 M10 M12 M14 M16
Steel
5
10
20
35
50
65
When closing the box, ensure that the seal is correctly
positioned.
As a general rule, check that no nut, washer
or other foreign body has fallen into the
motor housing.
25±1
38,5±1
7±1
15±1
15±1
15±1
22±1
15±1
15±1
15±1
22±1
15±1
38,5±1
15±1
35±1
40±1
55±1
40±1
35±1
20±1
30
±1
8±
1
13 x M6
16
±1
77,5
Dimensions in mm
4 x Ø13
Attachment
Attachment
97,5
54
Upper
connector
Intermediate
connector
Lower
connector
Earthing
connector
• PLSHRM motor terminal boxes
Holes (smooth holes) are drilled in the multi-level power connection bars, which are supplied without screws or nuts
to allow the user to adapt the connection to the connector cross-section.
U
W
V
Earthing
connector