HG200 - 200 Inverter
It is absolutely prohibited to
disassemble or access the internal parts of
the hoist without first cutting off the
power supply by pulling the plug out of
the power outlet.
The operator must work in a safe position,
i.e. so that the is protected against falling and
so that he has an unobstructed view of the
trajectory of the moving elements.
If the operator uses safety belts to protect
himself against falling, they must be
anchored to fixed parts and absolutely
immovable.
- Access to the area underneath the vertical
axis of the load must be prohibited to
persons or at least a sign must indicate the
danger due to suspended loads.
The user must still check that there are no
persons in the area underneath the vertical
axis of the load.
The loads must be lifted with a
vertical pull and therefore it is prohibited
to use the hoist with an oblique lift.
- It is recommended to sling the load
perfectly and to use adequate containers for
liquid or sandy substances.
- It is prohibited to use the lifting cable to
sling the load (see drawing).
- It is prohibited to grab or touch the
lifting cable while lifting or lowering the
load, in particular near the lifting limit
switch.
- The machine is built with an IP44 motor
meaning that it is protected against solid bodies
with sizes that are greater than one millimetre
and against water infiltration in all directions.
Therefore, it is prohibited to use the machine in
environments that are saturated with gas or if
exposed to direct streams of water or rain.
- It is also recommended to:
a) avoid overloading the hoist;
b) stop the lifting movement before the limit
switch trips since it should only be used in case
of emergency;
c) check that the voltage does not decrease
excessively during the start-up phase (this may
prevent the brake from opening);
d) make sure that the cable does not
completely unwind; at least 2 turns of the cable
must remain on the drum to avoid damage due
to the direct action of the load on the clamp
that attaches the cable.
The cable wound on the hoist drum has a
length that is greater than the maximum
foreseen use height.
e) (using the special set screw) place the
rotation shaft of the cable winder drum in a
horizontal position to guarantee that the cable
will be correctly wound on the drum.
f) The cable maximum winding diameter must
guarantee a free space on the sides of the drum
equal to 1,5 times the cable diameter.
Note: The manufacturer declines all
responsibility for injury to persons or
damage to property as a result of non-
compliance with the above-mentioned
standards.
MAINTENANCE
The entire device is built with class
A4 which corresponds to 84000 operating
Cycles.
The mechanism are built with class M4
which corresponds to 3200 h of operation.
After the number of operating cycles
described above, the machine must be
overhauled at a T.E.A. authorised service
centre.
English