background image

7

 

4

   

Functions and operations 

4.1 Power ON/OFF 

 

Press the power switch when the power is OFF to turn the power ON. 

When power is turned ON, the model is indicated, followed by internal oscillation emission or external synchronous emission. 

 

Operation

 

Display

 

When  the  power  is 
OFF 
 
 
 
 
 

Press the power 

switch 

 

 
 
 
 
 
 
 
 
 

 

 

 

 
 

Press the power switch when the power is ON to turn the power OFF, then the indication goes off. 

Operation

 

Display

 

When the power is ON 
 
 

Press the power switch 

 
 

 

 
 

*When the power is turned ON, the following indication may be displayed. 

The following indication is an error message when the reading previously used setting value fails. 
Press the “MODE” to return to normal emission screen from the error message display. 

Operation

 

Display

 

 
 
 
 

Press the “× 2”

 

 

 
 
 
 
 
 
 

Displayed 

“dt” for 0.5 sec. 

 

When turning the power on for the first time, “EXT FPM 

mode” is displayed. From the second time on, the same as 

when the power is previously turned OFF is displayed. 

 

Displayed the model for a sec. 

 

Returns to the normal emission screen 

 

Indicated letters go off 

 

Error message 

Содержание DT-3011P

Страница 1: ...STROBOSCOPE Read this manual thoroughly before use Beforeuse pleasecarefullyreadthesesafetyprecautions aswellasinstructions andfollow them forproperoperation www nidec com jp nidec shimpo INSTRUCTION...

Страница 2: ...ht source Mayresultineyeinjury Do not apply strongimpact to the unit or drop it Failuretofollowthiscouldresult inabnormal operation Avoidthefollowings Water directsunlight condensation dust dirt salt...

Страница 3: ...Mmodesetting INT 10 4 3 2PHAmode INT 12 4 4Externalsynchronousemission 13 4 4 1FPMmodesetting EXT 14 4 4 2PHAmodesetting EXT 15 4 5Functionmode 16 4 5 1Thesettingitems 16 4 5 2Instructionsaboutfunctio...

Страница 4: ...object frequency when such a still image appears Also a stroboscope can be used to make images of rotating or moving objects stand still or that slightlymoveinordertoobservetheirappearancein slow moti...

Страница 5: ...crew Thiscanbe attachedtothetripodforcameras Please usetheonehasadesignated screw 1 4 20UNCunder 8mmlong Xenon Lamp PowerSwitch PowerCable OperationPanel External signal I Oconnector Bodybuttom Screwh...

Страница 6: ...sandholdthisto savethecurrentdisplayandmode settings SIG Select Internal External Parametermode Internal oscillationemission referredtoas INT Flashbyinternal signal External synchronousemission referr...

Страница 7: ...T number Eachpressof LOAD switchesSELECT number 1to5 Numerical display StandardOperation indicatesflashrate PHAMode AngleandTimearedisplayed FunctionMode Each settingvalueisindicated Delaytypedisplay...

Страница 8: ...ration Display When thepowerisON Pressthepowerswitch WhenthepoweristurnedON thefollowingindicationmaybedisplayed Thefollowingindicationisanerrormessage whenthereadingpreviouslyused settingvaluefails P...

Страница 9: ...dial toreturntothepreviousdisplay 4 1 3HeatLamp Indicator When the ambient temperature of the Xenon lamp rises above a certain level the Heat Lamp Indicator will flash If the temperature risesmore the...

Страница 10: ...SIG switches INT and EXT Power OFF OFF Displaysthemodel PowerON FPMmode INT PHAmode PHAmode Savingfunction Readthesavedvalue SELECTnumber EXT Pressandhold Confirmsaving Returntotheprevious display FPM...

Страница 11: ...ond Onecycleis360 DisplayofINT 4 3 1FPMmodesetting INT Theemissioncount frequency canbe set inFPMmode TurnthedialinaCW directiontoincreasetheemissioncount andinaCCW directiontodecreaseit Turnthedialfa...

Страница 12: ...ssion count Press 2 to halve the current set the emission count Press MODE to switch to PHAmode FPMmode PHAmode If itisoverthan theflash range nothing will change on the display If itislowerthan thefl...

Страница 13: ...chtoPHAmode ms The phasecanbechanged by0 01 ms withintherangebetween0 00and999 99 ms and by0 1 ms withintherange between1000 0and1994 4 ms Atimelongerthanthelightemissioncyclecannotbeset PHAmodems Pre...

Страница 14: ...specificationsrange thefollowinglettersareindicated Without thedelayangle timesetting Measurablerange27to3300 fpm Withthedelayangle setting Measurablerange27to3300 fpm Withthedelaytimesetting Measurab...

Страница 15: ...14 4 4 1FPMmodesetting EXT Operation Display Press MODE to switch to PHAmode Press SIG to switch to INT INTFPMmode PHAmode Displayinthepreviousunit DEGorms EXTFPMmode...

Страница 16: ...mode DEG andPHAmode ms The phase can be changed by 0 01 ms within the range between 0 00 and 999 99 ms by 0 1 ms within the range between 1000 0and2216 0 ms Atimelongerthanthelightemissioncyclecannotb...

Страница 17: ...point F2 Triggeredgesetting forEXT Flashintherisingedge Flashinthefallingedge F3 Auto emission stop time setting Emission is performed continuously Stop emission automatically when no operation is pe...

Страница 18: ...mode1 youcansetweathertoadddecimalpoint NotreflectedonEXT Operation Display Change thesetting value Go to function mode2 TurnthepowerON whilepressing MODE Displays Func fortwoseconds Andmovetofunction...

Страница 19: ...ue Go to function mode3 Thissettingchangesthetimingof emissionasshowninthefollowingfigure Indicatesalternately Gotofunctionmode3 Previoussettingvalue Thedefaultsettingis L H CCW L H Risingedge CW H L...

Страница 20: ...nged Operation Display Change thesettingvalue Go to function mode4 Indicatesalternately Previoussettingvale Thedefaultsettingis 0 CCW CW Turnthedialanditwillstop indicatingalternately CW 1 CCW 1 Theti...

Страница 21: ...ettingvalue Go to function mode5 Indicatesalternately Gotofunctionmode5 Previoussettingvale Thedefaultsettingis OFF CCW CW CCW OFF Voltagepulseinput Pulldowntheexternalinputcircuit CW On Opencollector...

Страница 22: ...ration Display Change thesettingvalue Go to function mode6 Indicatesalternately Previoussettingvale Thedefaultsettingis 35000 CCW CW Turnthedialanditwillstop indicatingalternately Increase decreaseby1...

Страница 23: ...nal canbesetto400 secor150 sec Operation Display Change thesettingvalue Savethechanges and goto the homescreen Indicatesalternately Previoussettingvale Thedefaultsettingis 400 Gotothehomescreen CCW CW...

Страница 24: ...es the settingcanbesavedasfivepatterns 4 6 1Saving thesettingvalues The settingvaluesare savedasthefollowingfigure save cannot save Memory save Power OFF save INT EXT Power OFF during INT Power OFF du...

Страница 25: ...d LOAD SAvE andSELECTnumber thedefaultis 1 displayalternatelyevery0 5seconds TurnthedialandchangeSELECTnumbertosave CW 1 CCW 1 When 1 displaysonthescreen turnthedialCWtodisplay 5 When 5 displaysonthes...

Страница 26: ...gthe savingfunction Operation Display Thepowerswitch ON whilepressing 2 and MODE Press 2 and confirminitialization Press 2 and Confirminitialization ThepowerswitchON whilepressing 2 and MODE Displaysf...

Страница 27: ...de Theinitialsetting display Theinitial emission setting EXT Theinitialmode FPM Default SELECTnumber 0 1 INT FPM 1500 PHASE DEG 0 PHASE ms 0 EXT FPM 0 2 PHASE DEG 0 PHASE ms 0 F1 0 0 F2 L H F3 0 F4 OF...

Страница 28: ...andreadthesavingvaluesas thefigureon4 6 1 4 7 2How toreadthememory Operation Display Each pressof LOAD switchesSELECT numbers OFF 1 2 3 4 5 SELECT 1 OFF SELECT 0 SELECT 2 SELECT 3 SELECT 4 SELECT 5 Se...

Страница 29: ...ificationsand Pin assignment RM15WTRZB 8P HiroseElectricGroup Pinnumber Signal name Remarks 1 NC 2 NC 3 12V Power supplyforsensor 4 OUT External pulseoutput 5 IN External pulseinput 6 COM GND 7 NC 8 F...

Страница 30: ...mpedance 10k atvoltageinput 4 10 External pulse output Outputspulsestoexternal devicessimultaneously withlightemission Output circuit spec 12 V output Output pulse width about 400 s Output square wave...

Страница 31: ...emovethereflectorandInsert thelampinsertion holderasfarasitwillgo ThenturnitCW twoorthreetimesandpull outstraight withlamp Insertnewlampintothelampinsertionholder with seeigthefigurebelow Andpressitto...

Страница 32: ...Resolution 1 fpm Delayed emission function Measurement range 27 to 3300 fpm Within the range angle 0 to 359 available to set by1 Within the range time 0 00 to 999 99 ms available to set by 0 01 ms 100...

Страница 33: ...32 5 2Externaldimensions Powercable...

Страница 34: ...it failure Internal circuit failure Due to resolution The Xenon lamp life Internal circuit failure Internal circuit failure The Xenon lamp life It caanot be set below the second decimal place Troubles...

Страница 35: ......

Страница 36: ...Address 1 Terada Kohtari Nagaokakyo city Kyoto 617 0833 Japan Phone 81 75 958 3621...