background image

 

- 26  -

 

Table FG S-220VC  

M6 [mm] 

5.91

M8 [mm] 

0.39-1.26UNF 

M10 [mm] 

1.77

0.79

3.94

5.51

1.97

2-0.35 

3-0.22 

4-0.18 

1.57

Plate FGS-220VC  

0.79

0.79

5.91

Table Adjus t FGS-220/550VC 

1.77 adjustable 

Table 

1.31 adjustable 

[inch]

All manuals and user guides at all-guides.com

Содержание FGS-220VC

Страница 1: ...All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 2: ...All manuals and user guides at all guides com ...

Страница 3: ...Read Manual thoroughly prior to operation Use instrument only after reading the complete manual Follow all safety precautions All manuals and user guides at all guides com ...

Страница 4: ...uld be a possibility that it may cause more serious results Prot ection cat eg or ies are explained a nd separate d by the following symbols Proceed with Caution Not Allowed Prohibited Mandatory Must Follow Warning Heavy Take sufficient care while handling Ensure stand is placed on a flat level stable surface that can support the unit Do not operate in areas where explosive gases or vapors may be ...

Страница 5: ...ating temperature range 32 104 F 0 40 C Cleaning with thinner and gasoline etc Make sure the cable is not stuck in the stand Install the force gauge after turning off the power switch Adjust the limit switches when the motor stops When digital force gauge FGV series is installed Set ovEr in the F06 parameter which is the parameter of Output Type If ovEr is not set FGS VC does not stop by the overl...

Страница 6: ... the stand 4 4 3 Connection of PC to the stand 5 5 Operation 5 5 1 Basic operation flow 5 5 2 Operation mode 7 5 3 Manual operation mode 8 5 3 1 MANU mode 8 5 3 2 JOG mode 9 5 3 3 SING mode 11 5 3 4 CONT mode 14 5 4 Program operation mode 17 5 4 1 PROG mode 17 5 5 Parameter setting mode 21 5 6 Changing Engineering units 23 6 Message of status and error 24 7 Dimensions 25 8 Specifications 27 9 Trou...

Страница 7: ...ing procedures before use 1 2 Confirmation of product packing FGS VC 1 Cable to force gauge 1 Cable clip 1 USB cable 2m 1 Hex head spanner 1 Bolt M8 x 8mm 4 Socket bolt M6 x 16mm 2 Set screw M6 x 20mm 1 Washer 2 Manual 1 Confirm the parameter setting of the force gauge Install the force gauge Connect the cables Measure each mode Troubleshooting Problem All manuals and user guides at all guides com...

Страница 8: ...pushing the up or down arrows of the Speed key If the up or down arrows are held the speed adjusts continuously 3 Speed key Down 4 MAX key Push to override the current speed setting The speed will instantly go to the maximum capable of the stand Once released the speed returns to the previous speed setting This key only is functional in Manu or Jog modes 1 2 3 4 5 9 7 8 10 11 12 6 Emergency switch...

Страница 9: ... etc LCD display 4 Setup 4 1 Installation of force gauge Force gauge that can be connected with FGS VC is FGV series Force gauges up to 100kgf are compatible with the FGS 220VC Force gauges up to 200kgf are compatible with the FGS 550VC In case of FGS 220VC The force gauge is fixed to the stand The force gauge is set in the mounting plate Remove the mounting plate using the hex head spanner access...

Страница 10: ... of the force gauge Set the following parameters Measurement polarity RS232C baud rate 19 200 bps Refer to the manual of the force gauge Connect to FGS VC Connect the force gauge to FGS VC by the attached cable Power on Turn on the power of the force gauge Next turn on FGS VC with the power switch on the back Confirmation of the connection Display of FGS VC as follows 1 Indicates FGS 220VC 2 Indic...

Страница 11: ...l computer USB cable Cable between FGS VC and force gauge Force gauge power Turn on the power of the force gauge Keep hands hair and jewelry away from stand when drive assembly is in motion May cause damage or injury FGS VC power Turn on the power of the stand Example Tension test of a wire A wire Wedged chuck Solderless terminal Separate hands from the force gauge and FGS VC movable parts Turn on...

Страница 12: ...usage Mode can be changed by the Mode switch Start to measure Start each mode by pressing PUSH PULL or START switch Refer to each mode section FGS VC is able to test as follows Compression test Tension test Welding test Peel test Suction test Repulsion test Cork test Open test Etc All manuals and user guides at all guides com ...

Страница 13: ...essing PULL switch You want to move only while you press the PUSH key You want to move the round trip operation many times between limits of PUSH and PULL etc Select manual operation modes You wish to move complex operations e g You want to measure by specifying the positions The position of the object to be measured cannot be specified You want to combine a different direction PUSH PULL of operat...

Страница 14: ...occurs STOP button is pushed one of the limit stop switches is tripped or the emergency reset button is pushed MANU mode When pressing the PUSH PULL key FGS VC goes to PUSH PULL limit switch position FGS VC stops if reaching the limit position JOG mode This mode of operation is identical to MANU except that the movement in any direction will only occur while either the PUSH or PULL key is depresse...

Страница 15: ...e ZERO button 5 3 2 JOG mode Contents This mode of operation is identical to MANU mode except that the movement in any direction will only occur while either the PUSH or PULL button is depressed Speed Speed can be changed by UP or DOWN button of the SPEED key The speed setting of MANU and JOG mode is common Also the speed is able to be changed while moving Display Present position Setting speed Se...

Страница 16: ...hanged by UP or DOWN key of the SPEED Then press SET button for saving If you want to cancel the setting press ZERO button Setting speed The UP or DOWN button of the SPEED key can be used to change the speed The range is 0 40 15 75 in min 10 to 400 mm min All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 17: ...s selected The stand will continue to move until one of the following events occurs the STOP button is pushed one of the limit switches is tripped or the emergency reset button is pushed Upper limit Lower limit PULL Stop with upper limit switch ON with dwell timer Stop and complete with lower limit switch ON Display alternately Upper limit Lower limit PUSH Stop and complete with upper limit switch...

Страница 18: ...e changed while moving Display Repeat count Incremental count at pressing PUSH or PULL button The count is cleared with the ZERO button When the mode is changed the count will also be reset to zero Present position Setting speed Repeat count Moving direction Status of limit switch Setting dwell timer All manuals and user guides at all guides com ...

Страница 19: ...for saving If you want to cancel the setting press ZERO button Setting speed The UP or DOWN button of the SPEED can be used to change The range is o 40 15 75 in min 10 to 400 mm min Setting dwell timer The STOP button of the dwell time can be used to change Pressing STOP the dwell timer is incremental When the dwell timer is 5s it returns to 0s pressing STOP SET SET SET Saving return to SING mode ...

Страница 20: ...l continue to move until one of the following events occurs the STOP button is pushed the emergency reset button is pushed Display alternately B A Upper limit Lower limit PULL Stop with upper limit switch ON with dwell timer Stop with lower limit switch ON with dwell timer Complete with lower limit switch ON when the repeat count is reached A B Upper limit Lower limit PUSH Stop with upper limit sw...

Страница 21: ...e moving Display Repeat count Incremental count at pressing PUSH or PULL button The count is cleared with the ZERO button When the mode is changed the count will also be reset to zero Status of limit switch Setting dwell timer Present position Setting speed Repeat count Moving direction All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 22: ... DOWN button of the SPEED can be used to change The range is 0 40 15 75 in min 10 to 400 mm min Setting dwell timer The STOP button of the dwell time can be used to change Pressing STOP the dwell timer is incremental When the dwell timer is 5s it returns to 0s pressing STOP SET SET SET Saving return to SING mode SET Setting dwell timer The UP or DOWN button of the SPEED can be used to change The m...

Страница 23: ...ton is pressed The stand will continue to move until one of the following events occurs the STOP button is pushed one of the mechanical limit switches is tripped the emergency reset button is pushed or the overload of the force gauge is detected If the force limit of the condition setting is detected the present operation is interrupted and it will jump to next point operation Start point Program ...

Страница 24: ...elow Detect point Start point Start point Dwell timer P1 P3 P3 Dwell timer Return to Start point Return to Start point Dwell timer Present position Moving direction Operation status Setting speed Present repeat times t t All manuals and user guides at all guides com ...

Страница 25: ...ection of movement from Start point to Detect point The STOP button can be changed to Push or Pull alternately Detect object The force for detecting object can be set by PUSH or PULL button Speed The parameter is the speed setting for moving from Start point to Detect point The UP or DOWN button of the SPEED can be used to change SET SET Zero force After detecting the object the stand moves to opp...

Страница 26: ...om Start point to Detect point The UP or DOWN button of the SPEED can be used to change SET SET Dwell timer at P5 This parameter is the dwell timer Pressing STOP the dwell timer is incremental When the dwell timer is 5s it returns to 0s pressing STOP Previous page Setting P2 to P4 Speed at RET This parameter is the speed setting for moving from Point 5 to Start point The UP or DOWN button of the S...

Страница 27: ... 2 5 5 Parameter setting mode The relations function is set to the entire stand Contents The parameters are shown in the below table Items Description Range Sign of Push direction The sign at the position of the direction of Push is set If it sets and the stand moves to Push the display of position is decrement space Acceleration The acceleration of the motor of the stand is set The acceleration i...

Страница 28: ...r DOWN buttons Pressing the button the setting will be changed alternately SET MODE Save and go to MANU mode MODE Save and go to MANU mode Acceleration Adjust with the UP or DOWN buttons SET Volume of buzzer Adjust with the UP or DOWN buttons MODE Save and go to MANU mode SET All manuals and user guides at all guides com ...

Страница 29: ...ss SET key to go to FUNC4 Change in the displayed unit Pressing the PUSH or PULL keys changes the units from inch to mm Registration of the unit Press SET or MODE key to finish the setting Note The speed settings of JOG MANU SING CONT PROG go back to default when changing the units Press MODE key Press SET Press PUSH or PULL key All manuals and user guides at all guides com ...

Страница 30: ...Turn off and wait one minute then turn on Contact TECHNICAL SUPPORT if the alarm is not canceled The communication error between the controller and the motor driver in the stand occurred Turn off and wait one minute then turn on Contact to our technical support if the error alarm is not canceled The read error of the memory in the stand occurred Turn off and wait one minute then turn on If the err...

Страница 31: ...2 Press ZERO and SET button both turn on in keeping to press these buttons 7 Dimensions FGS 220VC 2 95 3 94 19 69 Lower limit Upper limit inch 4 72 Emergency switch Operation panel 11 81 2 95 Force gauge FGP FGPX All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 32: ...5 91 M8 mm 0 39 1 26UNF M10 mm 1 77 0 79 3 94 5 51 1 97 2 0 35 3 0 22 4 0 18 1 57 Plate FGS 220VC 0 79 0 79 5 91 Table Adjust FGS 220 550VC 1 77 adjustable Table 1 31 adjustable inch All manuals and user guides at all guides com ...

Страница 33: ...All manuals and user guides at all guides com ...

Страница 34: ... 28 Copyright Nidec Shimpo America Corporation 2013 All rights reserved Product specifications are subject to change without notice All manuals and user guides at all guides com ...

Страница 35: ...All manuals and user guides at all guides com ...

Страница 36: ...All manuals and user guides at all guides com a l l g u i d e s c o m ...

Отзывы: