![Niche C-BCH-0004 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/niche/c-bch-0004/c-bch-0004_operators-manual_1687472013.webp)
niche-industries.com
13
v.
FLOAT – when the battery is less than 14.3V (but more than
14.1V) the charger output is 2A. When the battery is fully
charged, the charger will automatically shut down and diagnose/
check the battery voltage, entering the maintain stage if the
battery voltage drops to 12.9V.
vi. MAINTAIN – the charger will automatically turn on if the battery
voltage drops below 12.9V. The battery charger will charge until
14.3V is reached with an output of 1.5A.
j. If the battery voltage indicator reads a voltage lower than 4.2V, the
LCD will display “LO,” and the charger will not charge the battery.
The battery charger considers anything lower than 4.2V to be a dead
battery.
k. The LCD display shows the battery state of charge by the percentage
on the battery bar. ( on diagram) The battery bar will flash as the
battery is being charged. The battery bar will increase as the battery
state of charge increases and will keep constant at 100% when it is
fully charged.
2. When DISCONNECTING the battery charger from the battery, first turn
off the charger, after that unplug the AC cord from the electrical outlet
and then disconnect the connection from the battery charger to the
battery.
NOTE: ALWAYS unplug the AC cord from the electrical outlet before
connecting (or disconnecting) the charger to (or from) the battery.
CHARGING INSTRUCTIONS