background image

WARNINGS:

• 

All technical specifications stated herein refer to an ambient temperature of 20°C (± 5°C) • Nice S.p.a. reserves the right to apply modifications to the

product at any time as deemed necessary, while maintaining the same functionalities and intended use • SYKCE guarantees the minimum number of manoeuvres per
day, exclusively with the photovoltaic panel positioned correctly and in the conditions as specified in Chapter 3.

PSY24 BATTERY

DESCRIPTION

DATA

Rated voltage:

24 V

Maximum current:

10 W

Rated battery capacity:

20 Ah

Protection rating:

IP 44 

Operation temperature:

- 20° C ÷ + 50 °C (0 °C, - +40 °C when charging using the back-up power supply unit connected to the mains)

Complete recharging time:

approx. 15 hours (when charging using the back-up power supply unit connected to the mains)

Dimensions:

258 mm x 235 mm x 180 mm

Weight:

14 kg

Note

– The batteries in the PSY24 unit are VRLA (Valve Regulated Lead Acid Batteries). They comply with the specific provision A67 of the IATA/ICAAO

regulation governing hazardous goods. PSY24 is therefore not considered hazardous goods and may be transported without any risk by air, sea and on
road.

SYP PHOTOVOLTAIC PANEL

DESCRIPTION

DATA

Rated voltage:

24 V

Peak power:

15 Wp

Operation temperature:

-40 °C ÷ +85 °C

Dimensions:

390 mm x 415 mm x 28 mm

Weight:

1,9 kg

Warning

– The glass of the photovoltaic panel has been tested to resist to hailstones and medium entity impact. In the event of particularly consistent hail

or impact, the glass may be damaged; in this case contact the Nice Technical Assistance service.

TECHNICAL SPECIFICATIONS

II

EN

EC declaration of conformity

Declaration in accordance with the Directives: 2006/95/EC (LVD) and 2004/108/EC (EMC)

Note

: The contents of this declaration correspond to declarations in the official document deposited at the registered offices of Nice S.p.a. and in partic-

ular to the last revision available before printing this manual. The text herein has been re-edited for editorial purposes. A copy of the original declaration
can be requested from Nice S.p.a. (TV) I.

Declaration number:

285/PSY(...)

Revision:

1

Language:

EN

Manufacturer’s name

: NICE S.p.A.

Address

: Via Pezza Alta N°13, 31046 Rustignè di Oderzo (TV) Italy

Type of product

: Nice solar kit

Model / Type

: SYKCE kit comprises the SYP photovoltaic panel and the PSY24 battery

Accessories

: SYA1

The undersigned, Luigi Paro, in the role of Managing Director, declares under his sole responsibility, that the product specified above conforms to the pro-
visions of the following directives:

• Directive 2006/95/EC OF THE EUROPEAN PARLIAMENT AND COUNCIL of 12 December 2006 regarding the approximation of member state legisla-

tion related to electrical material destined for use within specific voltage limits, according to the following harmonised standards:
EN 60335-1:2002 + A1:2004 + A11:2004 + A12:2006 + A2:2006 + A13:2008

• DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND COUNCIL of 15 December 2004 regarding the approximation of member state leg-

islation related to electromagnetic compatibility, repealing directive 89/336/EEC, according to the following standards:
EN 61000-6-2:2005, EN 61000-6-3:2007

Oderzo, 17 March 2010

Ing. 

Luigi Paro

(Managing director)

Содержание Solemyo PSY24:

Страница 1: ...Solemyo EN Installation and use instructions and warnings Autonomous power system SYKCE PSY24 ...

Страница 2: ...tismo si no estuviera también conectado el panel fotovoltaico y que fun cione correctamente Si el acumulador no estuviera bien recarga do agotará su reserva de energía en pocos días Si el automatismo no se utilizara por mucho tiempo se aconseja desconectar los conectores del automatismo y del panel fotovol taico del acumulador y guardar este último en un lugar fresco y seco DEUTSCH ACHTUNG Wenn di...

Страница 3: ...ontal line that intersects the line of the values of cycles day The result is the maximum number of cycles daily performed by the automation Our example see fig 1 Automation installed RB1000 B Required period of the year Cb 6 Type of standby safeties B 0 9 acces sory 1 MOFB photocell B 0 7 Total B 1 6 Y Y Cb B 6 1 6 4 4 K lightweight leaf 4 accessory 1 Lucy B flashing light K 1 Total K 5 Ks s last...

Страница 4: ... by SYP during the hours of sunlight making it available at any time of day including days with adverse weather conditions The same device can also store energy from the fixed electrical mains via SYA1 The pack con tains the PSY24 battery cables connectors for automation connections fix ing hardware and this manual SYP this is a device able to convert sunlight directly into electrical energy The p...

Страница 5: ...tude at all times of the calendar year with the automation pow ered exclusively using PSY24 and SYP devices The graph curve is generat ed taking into account the quantity of daylight recorded at a specific latitude within a year To obtain the maximum possible number of cycles per day proceed as fol lows 01 On graph A B or C depending on the latitude of your system identify the period of the year c...

Страница 6: ... the various elements of the socket on the cable taking care to observe the sequence as shown in fig 7 IMPORTANT If the power cable in the pack is used out doors it must be entirely protected with special ducting suit able for the protection of electric cables CAUTION Do not modify the electric jumper on the connector fig 8 02 Using a slotted screwdriver attach the blue wire to terminal n 1 on the...

Страница 7: ...he devices to the retailer when purchasing new equivalent versions Caution local legislation may envisage serious fines in the event of abusive disposal of these devices PSY24 Battery disposal Caution The battery contains pollutant substances after removing never dispose of as standard waste Dispose of or recycle according to current local standards WHAT TO DO IF troubleshooting guide PERIODIC MAI...

Страница 8: ...n this case contact the Nice Technical Assistance service TECHNICAL SPECIFICATIONS II EN EC declaration of conformity Declaration in accordance with the Directives 2006 95 EC LVD and 2004 108 EC EMC Note The contents of this declaration correspond to declarations in the official document deposited at the registered offices of Nice S p a and in partic ular to the last revision available before prin...

Страница 9: ...l pannello fotovoltaico FR Assemblage de la patte de support du panneau photovoltaïque ES Ensamblaje del soporte del panel fotovoltaico DE Zusammenbau des Haltebügels des Kollektors für Photovoltaik PL Składanie uchwytu mocującego panelu fotoelektrycznego NL Montage van de draagbeugel van het zonnepaneel 1 A 1 B 3 n 10 ...

Страница 10: ...X S E W N 90 90 90 90 4 5 6 ...

Страница 11: ...XI 2 3 1 4 1 4 4 7 9 11 a 11 c 11 b 8 10 12 ...

Страница 12: ...XII 205 mm 13 mm 13 mm 256 mm 128 mm 122 mm 230 mm 208 mm IN OUT 13 14 15 17 18 16 a 16 b ...