37
6HOHFWDEOHIXQFWLRQV
To select the required functions set the programming dip switches to Off and activate the functions dip switches
as shown in the following list:
Switch 1-2 Off Off = "Manual" movement, i.e. hand operated
On Off
= "Semiautomatic" function
Off On
= "Automatic" function, i.e. Automatic Closing
On On
= "Aut Always close" function
Switch 3
On
= Condominium function <Not available in Manual mode>
Switch 4
On
= 5 s preflashing (2 s in manual mode)
Switch 5
On
= Re-close 0 s after Photo if in automatic mode or re-close after Photo if in
semiautomatic mode
Switch 6
On
= Photo also during opening
Switch 7
On
= Phototest activation
Switch 8
On
Off
=
=
Suction cup
Electric lock
Switch 9
On
= Traffic light in one-way mode
Switch 10 On
= Traffic light in both directions
1RWH
Setting dip switches to the "Off" position servers to inhibit the associated function.
)XQFWLRQVGHVFULSWLRQ
0DQ3UHVHQW)XQFWLRQ
The movement is performed only when the command is present. The movement stops as soon as the command
is suspended, when one of the safety devices trips ("Stop" or "Photo") or if the current sensor trips.
Once the manoeuvre has been interrupted the input command must be deactivated before another command can
be transmitted to start a new movement.
6HPLDXWRPDWLFDQGDXWRPDWLFIXQFWLRQ
In "Semiautomatic" or “ Automatic” mode following a command pulse the entire movement is executed until
the specified position is reached. A second pulse on the same input that started the movement will cause a
system Stop. If a control input is supplied with a continuous signal instead of a pulse, this will result in a
priority condition wherein all the other control inputs are disabled (this function is useful, for example, if a
clock is to be connected to the opening input). Tripping of the current sensor or a photocell involved in the
direction of motion during a manoeuvre ("Photo" during the closing manoeuvre) will result in a direction
reversal.
In Automatic operating mode, an opening manoeuvre will be followed by a pause and then a closing
manoeuvre. If the "Photo" safety device trips during the pause interval, the timer will be reset with the preset
pause time; if the "Stop" input trips during the pause interval the re-close function will be cancelled and the
system will assume Stop status.
$OZD\V&ORVHIXQFWLRQ
Automatically starts a close manoeuvre preceded by 5 seconds of preflashing if "bar open" status is detected
when power is restored.
&RQGRPLQLXP)XQFWLRQ
In "Condominium" mode an opening manoeuvre cannot be interrupted by control pulses except for those that
result in a closing manoeuvre. During the closing movement a new control pulse will cause the movement to
stopped and reversed (opening movement).
3UHIODVKLQJ
A command impulse activates the flashing light, followed by movement 5 seconds later (2 seconds later in
manual mode).
5HFORVHVHFRQGVDIWHU3KRWRLILQDXWRPDWLFPRGHRUUHFORVHDIWHU3KRWRLILQVHPLDXWRPDWLFPRGH
In automatic mode tripping of the photo safety device in the opening or closing manoeuvre reduces the pause
time to 0 seconds irrespective of the preset pause time. In semiautomatic mode tripping of the photo safety
device in the closing manoeuvre activates automatic closing with the preset pause time.
3KRWRDOVRGXULQJRSHQLQJ
With this function tripping of the "Photo" safety device causes an interruption of the movement also during the
opening manoeuvre; if the "Semiautomatic" or "Automatic" function is selected, after the "Photo" device is
disengaged the opening movement will be resumed.
Содержание Signo