10
– ENGLISH
a
The gate cannot be commissioned partially or un-
der “temporary” conditions.
To commission the automation:
1.
compile the automation’s technical file, which must include
the following documents: overall drawing of the automa-
tion, wiring diagram, risk assessment and relative solutions
adopted, the manufacturer’s declaration of conformity for all
devices used and the declaration of conformity compiled by
the installer
2.
permanently affix a label or plate near the manual manoeu-
vre knob, indicating the operations for unlocking the shutter
“
Figure
19
3.
permanently affix a label or sign to the door with the follow-
ing image (minimum height 60 mm) “
Figure
20
4.
affix a label to the door containing at least the following data:
type of automation, name and address of manufacturer (per-
son responsible for commissioning), serial number, year of
manufacture and the CE mark
5.
compile the declaration of conformity of the automation and
hand it to the owner of the automation
6.
compile the User Manual of the automation and hand it to
the owner of the automation
7.
compile and provide the owner with the automation’s “Main-
tenance schedule”, containing the maintenance instructions
for all the automation’s devices.
l
For all the above-mentioned documentation, Nice –
through its technical assistance service – provides
the following: pre-completed forms.
TROUBLESHOOTING...
(troubleshooting guide)
7
7
TROUBLESHOOTING GUIDE
7.1 TROUBLESHOOTING
The table below contains useful instructions to resolve any malfunctions or errors that may occur during installation or in case of a fault.
Table 2
TROUBLESHOOTING
Problems
Recommended checks
The motor does not start
Verify that the connections shown in the electrical diagram are correct.
If the motor is equipped with an electric brake, verify that it is properly connected to
the limit switch casing.
On the version without brake, a jumper must be connected between the two
terminals.
The shutter does not stop in the pre-defined
positions
Verify that the limit switch is properly adjusted as set forth in the "
" paragraph.
The manual manoeuvre knob is unlocked, but the
shutter cannot be lifted
Verify that the cord of the electric brake was suitably tensioned during the
installation phase.
Verify that the spring support boxes are not damaged.
The thermal cut-off was activated
The motor has overheated: wait until its normal temperature is restored.
The motor struggles to lift the shutter
Verify that the size and weight of the shutter are compatible with the gearmotor’s
installation.
Verify the correct operation of the spring support boxes.