EN
English –
5
2.2) Typical system
Figure 2 shows a typical system for automating a sliding gate using ROBUS
2
1
Key-operated selector switch
2
Photocells on post
3
Photocells
4
Main fixed edge (optional)
5
Main movable edge
6
“Open” stop bracket
7
Rack
8
Secondary fixed edge (optional)
9
Flashing light with incorporated aerial
10
ROBUS
11
“Closed” stop bracket
12
Secondary movable edge (optional)
13
Radio-transmitter
2.3) List of cables
Figure 2 shows the cables needed for the connection of the devices in a typical installation; table 3 shows the cable characteristics.
!
The cables used must be suitable for the type of installation; for example, an H03VV-F type cable is recommended for indo-
or applications, while H07RN-F is suitable for outdoor applications.
Note 1:
power supply cable longer than 30 m may be used provided it has a larger gauge, e.g. 3x2,5mm
2
, and that a safety grounding
system is provided near the automation unit.
Note 2:
If the “BLUEBUS” cable is longer than 30 m, up to 50 m, a 2x1mm
2
cable is needed.
Note 3:
A single 2x0,5mm
2
cable can be used instead of two 4x0,5mm
2
cables.
Note 4:
Please refer to Chapter “7.3.2 STOP Input” in situations where there is more than one edge, for information about the type of con-
nection recommended by the manufacturer.
Note 5:
special devices which enable connection even when the leaf is moving must be used to connect movable edges to sliding leaves.
Connection
Cable type
Maximum length allowed
A:
Power line
1 3x1,5mm
2
cable
30m (note 1)
B:
Flashing light with aerial
1 2x0,5mm
2
cable
20m
1 RG58 type shielded cable
20m (recommended less than 5 m)
C:
Photocells
1 2x0,5mm
2
cable
30m (note 2)
D:
Key-operated selector switch
2 2x0,5mm
2
cable (note 3)
50m
E:
Fixed edges
1 2x0,5mm
2
cable (note 4)
30m
F:
Movable edges
1 2x0,5mm
2
cable (note 4)
30m (note 5)
Table 3: List of cables
2
4
3
3
8
10
2
6
11
7
9
13
12
5
1
E
C
F
D
C
F
A
B