ENGLISH –
17
TROUBLESHOOTING...
(troubleshooting guide)
7
7
TROUBLESHOOTING GUIDE
Some devices are configured for signalling the operating status or the presence of any anomalies.
7.1 SIGNALLING THROUGH WARNING LIGHT
If a warning light is connected to the FLASH output (
A
) on the
control unit, the light will flash once every 1 second while the
manoeuvre is being performed.
If any anomalies occur, the warning light will emit shorter flashes
which are repeated twice with a 1-second pause in between. “
” describes the cause and possible solution for each type
of anomaly signalled by the warning light.
OGI
5
ELS
Flash
A
M
M
21
Table 9
SIGNALS OF THE WARNING LIGHT CONNECTED TO THE FLASH OUTPUT (“
FIGURE
Flashes
Anomaly
Possible solution
1 short red flash
1-second pause
1 short red flash
BlueBus system error
The check to verify the devices connected to the BlueBus system, run at
the start of the manoeuvre, does not reveal the same devices memorised
during learning phase. There may be some disconnected or faulty devices:
check these and replace them if necessary. Some changes were made:
the device learning procedure must be rerun.
2 short red flashes
1-second pause
2 short red flashes
Intervention of a photocell
One or more photocells do not consent to the movement or have caused
the latter to reverse. Check for any obstacles.
3 short red flashes
1-second pause
3 short red flashes
Intervention of the
“Obstacle Detection”
function through the force
limiter
During the gate’s movement, the motors encountered more resistance.
Verify the cause and increase the motor force if necessary.
4 short red flashes
1-second pause
4 short red flashes
Intervention of the STOP
input
At the start of the manoeuvre or during the movement itself, the devices
connected to the STOP input intervened. Identify the cause.
5 short red flashes
1-second pause
5 short red flashes
Error in the internal
parameters of the control
unit
Wait at least 30 seconds then try giving a command and disconnect the
power supply if necessary. If the condition persists, there may be a serious
malfunction and the electronic board needs to be replaced.
6 short red flashes
1-second pause
6 short red flashes
The maximum limit for
consecutive manoeuvres or
manoeuvres per hour has
been exceeded
Wait for a few minutes until the manoeuvre limiting device drops to under
the maximum limit.
7 short red flashes
1-second pause
7 short red flashes
Electric circuit anomaly
Wait at least 30 seconds then try giving a command and disconnect the
power supply if necessary. If the condition persists, there may be a serious
malfunction and the electronic board needs to be replaced.
8 short red flashes
1-second pause
8 short red flashes
A command that prevents
other commands from being
executed is already present
Check the type of the “always present” command (for example, it could be
a command from a clock on the AUX input).
9 short red flashes
1-second pause
9 short red flashes
The automation was
stopped by a “Stop
automation” command
Unlock the automation mechanism by giving the “Unlock automation”
command.
10 short red flashes
1-second pause
10 short red flashes
Intervention of the
“Obstacle Detection”
function from the encoder
The motors were hampered by greater friction during their movement.
Identify the cause.
Содержание MC824HHS
Страница 1: ...Nice MC824HHS Control unit EN Instructions and warnings for installation and use...
Страница 24: ...24 ENGLISH NOTES...
Страница 26: ...26 ENGLISH NOTES...
Страница 27: ...ENGLISH 27 NOTES...
Страница 28: ...www niceforyou com Nice SpA Via Callalta 1 31046 Oderzo TV Italy info niceforyou com IDV0779A00EN_27 11 2020...