7.6 - Master - Slave mode
This operating mode is used if it is necessary to automate 2 counterposed bar-
riers which perform synchronised movements. In this mode, a barrier works as
Master and commands the manoeuvres, while the second works as Slave and
carries out the commands sent from the Master barrier; by default all the barri-
ers are set as Master.
To configure the barrier as Slave it is necessary to activate the level 1 function
“Slave Mode” (see Table 7).
The connection between Master and Slave takes place through the BusT4 with
the dedicated Master/Slave connector.
Important! – Should the Oview programmer be used, it is necessary to
modify the parameter “Together” or “Address” of one of the 2 barriers.
This is to avoid the simultaneous communication of the 2 control units
with the Oview programmer.
7.6.1 - Installation and electrical connections
Warnings
• All the devices, including the radio receiver, must be connected on the Master
barrier;
• If the buffer battery is used, each barrier must have its own;
• In the
Slave
barrier it is possible to carry out the following connections:
- its own flashing light (Flash)
- its own Pole Open Indicator (S.C.A.)
- pole lights
- its own sensitive edge (Stop)
- its own command device (P.P.), which commands the total opening of
the Slave pole only
- the Open and Close inputs are not used
- the Loop1 and Loop2 inputs programmed with “Open” mode
- the receiving radio
To install 2 barriers and program them with “Master - Slave” mode, proceed as
follows:
01.
Install the 2 barriers (
fig. M
).
It is not important which of the two works as Master or Slave; it is neces-
sary to assess the convenience to create the electrical connections and
that the “Step-Step” command that will carry out the Slave barrier will pro-
vide the total open
of the
Slave pole only;
02.
Connect the two control units one to the other through the Master/Slave
connector (
fig. 54
), respecting the polarity indicated;
03.
At this point, carry out the other electrical connections (
fig. 54
), referring to
the indications contained in chapter 4 - Electrical connections;
H
5 mm - 8 mm
Sealant
Groove
String
Loop
(the cable
must be inser-
ted in the
groove)
Connection
(twisted cable)
Groove
5 - 8 mm
Earth
Twisted cable
I
L
F
approximately 0,35 m
Direction of travel
LOOP1 LOOP2
LOOP1 LOOP2
Route
1 m
30 mm -
50 mm
Содержание M3BAR
Страница 2: ......
Страница 26: ......
Страница 30: ...II 4 3 b a c d g h f e c a b...
Страница 31: ...III 5 6 MBAR a c d b...
Страница 32: ...IV 90 8 9 MBAR a b c a b 7 a b...
Страница 33: ...V 180 10 11 LBAR c a a b...
Страница 34: ...VI 13 14 12 LBAR c a b...
Страница 35: ...VII 15 16 18 17...
Страница 36: ...VIII 19 20 21 23 22...
Страница 37: ...IX 24 26 25 28 1 cm 27 29...
Страница 38: ...X 33 34 30 31 32 c a b c a b...
Страница 39: ...XI 35 36 37 45 38 a b a b c...
Страница 41: ...XIII 42 43 44 STOP 45 46 LIGHT 47...
Страница 42: ...XIV 48 49 50 a b c...
Страница 43: ...XV 51 52 a b...
Страница 44: ...XVI 53 a b c d e f g...
Страница 46: ...XVIII F1 F1 F2 F2 55...
Страница 47: ......
Страница 48: ...ISTML BARR01 4865_07 10 2011 www niceforyou com Nice SpA Oderzo TV Italia info niceforyou com...