OPEN MECHANICAL RELEASE
1. Lift up the rubber key cap (Detail 1).
2. Insert key and turn 90° clockwise (Detail 2).
3. Lift up the mechanical release (Detail 3).
4. After mechanical release is opened, the actuator arm can now be freely extended and retracted
manually.
2
3
1
FIG-6:
OPEN ACTUATOR MECHANICAL RELEASE (DETAIL A, B, C)
NOTICE
If manual extension is not possible, the actuator must be partially extended using the motor once the
actuator is powered by the control board.
To extend actuator using motor, close the mechanical release and momentarily press the OPEN Button
(Push-To-Open) or CLOSE Button (Pull-To-Open) to extend the actuator beyond it’s fully retracted state,
then press the STOP Button. Open the mechanical release again and manual extention should be possible.
IMPORTANT!
The actuator key MUST be left with the customer.