3
INSTALLATION
3.1 - General installation notes
1. Make sure the alarm sound can be easily audible in other rooms in the building.
2. Install the sensor in already decorated, painted rooms.
3. Install the sensor at least 1.5m from air conditioners.
4. Do not install the sensor in direct sunlight. Keep at least 0.5m distance from light sources.
5. Do not install the sensor in places prone to drafts.
6. Do not install the sensor in places with high water vapor condensation, e.g. above stoves, ovens, kettles, etc. The device can not be
installed where the temperature exceeds operational values (0°C – 55°C).
7. Do not install the sensor in areas where the temperature exceeds the maximum temperature rating (0°C – 55°C).
8. There should be at least one sensor on each floor.
9. If there is only one sensor on a floor, it is best to place it in the corridor leading to the bedrooms.
10. It is recommended to install the sensor in every room except kitchens and bathrooms.
11. In standard rooms up to 60 m², one sensor is sufficient, except for L-shaped rooms or bigger rooms.
12. If the room has high furniture, fittings, or other high dividers, it is recommended to install more sensors.
13. In standard corridors (up to 3 m), it is recommended to use smoke detectors every 15 m maximum. If the corridor is L or U-shaped, instal-
lation in the middle of the corners is recommended.
14. The sensors must not be painted over or covered with furniture.
15. When installing on sloped ceilings, the sensor should be installed in a horizontal position. For slopes greater than 20 degrees, it is recom-
mended to install the sensor 50-100 cm from the highest part of the ceiling.
3.2 - Recommended place of installation
It’s recommended to install the sensor on the ceiling or upper portion of the wall at least 40cm (2 feet) from corners and other objects. Particu-
lar attention should be paid to any adjacent objects or devices which can impede smoke’s access to the sensor. It’s recommended to install
Smoke-Control in all rooms prone to fire and between such rooms.
3.3 - Sensor installation
To install the device properly, follow the procedure:
1. Include the device into the Z-Wave network. Note the inclusion process may be performed ONLY in direct range of the main controller.
2. Install the sensor’s cover in desired location.
3. Screw Smoke-Control into the cover.
4. If the sensor is already included into the Z-Wave network, wake it up by clicking the B-button. Otherwise, add the device as described in
chapter 4.
5. Test Smoke-Control’s operation by performing a self-test - press and hold the B-button.
6. Test the Z-Wave network range (see p.XIV) assuring the device is within range.
4
ADDING THE DEVICE
• Adding in security mode must be performed up to 2 meters from the controller.
• In case of problems with adding the device, please reset the device and repeat the adding procedure.
Adding (Inclusion) -
Z-Wave device learning mode, allowing to add the device to existing
Z-Wave network.
To add the device to the Z-Wave network
manually
:
1. Install the battery. Visual indicator will signal the Z-Wave network adding status (red -
device ready for inclusion, green - device added, remove firstly).
2. Make sure the device is located within direct range of the Z-Wave controller.
3. Set the main controller into the adding mode (see main controller’s operating manual).
4. Quickly, triple click the B-button, located on Smoke-Control’s casing (Fig. 1).
5. Smoke-Control will be detected and added to the Z-Wave network.
Fig. 1. Smoke-Control top view
B-BUTTONAND
VISUALINDICATOR