background image

4

3.3) Electrical connections

The power supply and communication of the F210S comes
through the TTBUS connection of the motor or control unit.
The connection is not polarized, use a cable with a minimum
section or 0.5 mm2 and no longer than 30 m. 

The motor or control unit must be disconnected

when connecting the F210S.

“Up”, “Stop” and “Down” buttons can be connected to the
RX receiver (see figure 9). The Step-by-Step function (open-
stop-close-stop) can be obtained by connecting the OPEN
and CLOSE inputs in parallel and controlled by the same
push-button.

If a sensitive edge is used, then the standard 8.2K

resist-

ance on the RX terminals reserved for the connection of the
sensitive edge is removed and used as a terminal for the sen-
sitive edge, or is not used if the edge has its own terminal
resistance. If the sensitive edge is not used then the 8.2K

resistance is left connected to terminals 3 and 4.

If the sensitive edge has 2 outputs with 2 separate NC con-
tacts, it can be connected as shown in figure 8 placing the
8.2K

resistance in series between the two contacts. Make

sure that the sensitive edge complies with the failsafe cate-
gory 3 according to the EN 954-1 standard.

Do not use sensitive edges that have only one NC

type contact because they do not have the necessary
failsafe category required by the said standard.

To deactivate the short inversion when the sensitive edge
cuts in, such as when the edge touches the ground, a switch
S can be used with a series resistance of 8.2K

that is con-

nected in parallel with the sensitive edge (see figure 9). If con-
tact S closes in proximity to the closure of the shutter or ver-
tical door, when the sensitive edge touches the floor, the
automation blocks without inverting the movement and the
door remains closed. In this situation only the up manoeuvre
can be performed. This condition is signalled by the DL1 LED
(Sensitive edge) which briefly turns off every 2 seconds.

!

!

3.

Fix the photocells as shown in fig. 6.

4.

Direct the lenses as in fig. 7 in order to obtain the correct alignment between the TX and RX.

5.

Carry out the electrical connections following that which is indicated in the motor or control unit instructions manual. Also
see the connection examples in chapter 3.3 “Electrical connections”.

6

7

8

Содержание F210S

Страница 1: ...ed avvertenze per l installatore Instructions et avertissements pour l installateur Anweisungen und Hinweise f r den Installateur Instrucciones y advertencias para el instalador Instrukcje i ostrze e...

Страница 2: ...f interest to end users The use of F210S which is not explicitly provided for in these instructions is not permitted Improper use may cause damage and personal injury Do not modify any components unle...

Страница 3: ...for clarification Only one pair of F210S photocells can be used for each motor or control unit never connect more than one pair of F210S photocells in parallel The F210S photocells use a synchronising...

Страница 4: ...ance in series between the two contacts Make sure that the sensitive edge complies with the failsafe cate gory 3 according to the EN 954 1 standard Do not use sensitive edges that have only one NC typ...

Страница 5: ...sufficient the connection shown in figure 10 can be made placing the OPEN and CLOSE inputs in parallel Maintain the 8 2K resistance on the sensitive edge input STEP BY STEP 3 3 3 Connection of 2 or mo...

Страница 6: ...lly lasts just a few sec onds but can last up to as much as a minute 9 If communication occurs correctly the DL1 LED SENSI TIVE EDGE must be off and the DL2 PHOTOCELL must be flashing If this is not s...

Страница 7: ...n be useful to distinguish faults or resolve possible problems DL1 LED SENSITIVE EDGE Meaning Action DL2 LED PHOTOCELL Meaning Action Sensitive edge Ok Table 1 Off 8 2K resistance on the sensitive edg...

Страница 8: ...been connected As for the installation the disposal of the product at the end of its effective life must be performed by qualified personnel This product is made of various types of materials some of...

Страница 9: ...Protection class casing IP44 Operating temperature 20 55 C Dimensions weight 46 x 128 h 45mm 230 g Max cable length If the measured value passes to 4 1 K 20 for at least 300 ms before dropping below...

Отзывы: