background image

Page 3

Wiring:

Relay 1 

Lock Output

NC

COM

NO

Alarm output, Free exit

push button and Door

monitoring input

ALM

FRX

PB

0v

Door

Relay 2 

Aux Output

NC

NC

COM

NO

Operating

power

input

0v

+12-24v

0v

+v

Use the INI4007
diode when 
power is DC.

Use the INI4007 diode, 
as power can only be DC.

Mag-lock example

Strike-lock example

4007

4007

470X

Use the 47pf 
capacitor when 
power is AC.

LED Indications:

Power LED

Green LED

Relay 1 

(Lock output)

Amber LED

Relay 2

(Auxiliary output)

Red = Normal operating mode

On = relay active

On = relay active

Yellow = Programming mode active

Off = relay inactive

Off = relay inactive

Flashing = Alarm activated since last 

valid user entered/exited. 

Enter any valid user code twice to clear 

alarm memory.

Nice

Power LED

Green LED

Amber LED

Содержание EPad

Страница 1: ...rbell When multiple incorrect codes have been entered consecutively When Aux code is entered Each relay has its own LED indicator for relay status indication at a glance Relay 1 Lock output can be activated to latch on temporarily while in pulse mode using the unique Bypass code Specifications Operating voltage 12 24v AC DC Maximimum standby current 100mA Maximum load on dry contact relay outputs ...

Страница 2: ...tch input terminal connection 6 Relay 2 Aux Output terminal connections 7 System Restore Factory Default dipswitch 8 Bypass Door monitoring dipswitch 9 Bypass Tamper switch monitoring dipswitch 10 Built in tamper switch 1 Remove power 2 Switch System restore switch on 3 Re apply power 4 Wait for buzzer to tone conitinuously 5 Switch System restore switch off All settings and features are now retur...

Страница 3: ...nly be DC Mag lock example Strike lock example 4007 4007 470X Use the 47pf capacitor when power is AC LED Indications Power LED Green LED Relay 1 Lock output Amber LED Relay 2 Auxiliary output Red Normal operating mode On relay active On relay active Yellow Programming mode active Off relay inactive Off relay inactive Flashing Alarm activated since last valid user entered exited Enter any valid us...

Страница 4: ...determine the length of all user codes Lock Aux and bypass users i e the default master code is 1234 Therefore all user codes will be 4 digits long unless the master code is changed If the master code length is changed after user codes have already been programmed the following will occur Master code shortened the last digits of the user code will be dropped making the user codes the same length a...

Страница 5: ... LOCKS When the Bypass code is entered Relay1 Lock output latches on until the bypass code is re entered or when the FRX push button is used Enable the bypass code function Type in Master Code Master Code chime tone 52 1 chime tone Disable the bypass code function Type in Master Code Master Code chime tone 52 0 chime tone Deleting an individual user code Type in Master Code Master Code chime tone ...

Страница 6: ...ble bypass mode 52 1 Disabled Disable bypass mode 52 0 Default Set bypass code 52 New unique bypass code None Alarms and Security Enable multiple incorrect code lock out Anti hacking feature 51 to toggle between enabled or disabled Disabled Disable Alarm output mode 55 0 Disabled Door monitoring forced open or jammed open alarm 55 1 Door open time Relay 1 Lock output pulse length Disabled Tamper a...

Страница 7: ...m Door not closed by the time the Relay1 Lock output returns to standby status Door jammed open alarm Keypad housing opened Tamper alarm After the alarm time set by the installer has expired the alarm output and the built in buzzer resets However the flashing green LED continues until the first valid user code is entered into the keypad This way the user is made aware that an alarm condition occur...

Страница 8: ...isqualify this product from the warranty as laid out above These conditions are non negotiable 1 Any unauthorized non manufacturer modifications to the product or components thereof 2 Any modification to the installation methods described in the installation instructions 3 Any application or use of the product other than the intended use and application prescribed in the product documentation The ...