English –
12
Z-WAVE SPECIFICATION
6
The device is a Security Enabled Z-Wave Plus™ product and a
Security Enabled Z-Wave Controller must be used in order to
fully utilize the product.
The device may be used with all devices certified with the Z-Wave Plus
certificate and should be compatible with such devices produced by
other manufacturers.
The device works as a Z-Wave signal repeater (all non-battery operated
devices within the network will act as repeaters to increase reliability
of the network).
Generic Device Type:
GENERIC_TYPE_SWITCH_MULTILEVEL
Specific Device Type:
SPECIFIC_TYPE_CLASS_C_MOTOR_CON-
TROL
TABLE E
– Supported Command Classes
Command Class
Version
Secure
ZWAVEPLUS_INFO
2
SWITCH_MULTILEVEL
4
YES
ASSOCIATION
2
YES
CONFIGURATION
2
YES
SCENE_ACTIVATION
1
YES
SCENE_ACTUATOR_CONF
1
YES
NOTIFICATION
8
YES
APPLICATION_STATUS
1
ASSOCIATION_GRP_INFO
1
YES
TRANSPORT_SERVICE
2
VERSION
2
YES
MANUFACTURER_SPECIFIC
2
YES
DEVICE_RESET_LOCALLY
1
YES
POWERLEVEL
1
YES
SECURITY
1
SECURITY_2
1
SUPERVISION
1
FIRMWARE_UPDATE_MD
4
YES
TABLE F
– Association Command Class
Group Group Name
Profile
Max.
Nodes
Supported
Description
1
Lifeline
General:
Lifeline
5
Reports the device status to
the Z-Wave controller.
2
Retransmit
General:
NA
5
Retransmits Basic Set, Mul-
tilevel Switch Set, Multilevel
Switch Start Level Change,
Multilevel Switch Stop Level
Change or Scene Activate
Set to the associated
nodes.
3
Configuration
General:
NA
5
Retransmits configura
-
tion for parameters 39..43
(Configuration Bulk Set or
Configuration Set) to the
associated nodes.
TABLE G
– Multilevel Switch Command Class / Basic CC Mapping
Basic Command
Mapped Command
Basic Set (Value)
Multilevel Switch Set (Value)
Basic Report (Current Value, Duration) Multilevel Switch Report (Value, Dura-
tion)
TABLE H
– Multilevel Switch Command Class SET
Value
Duration
Level
Description
0x00
Ignore
0%
Close
0x01..0x63
Ignore
Lowest non zero level ..
100%
Set level .. Fully open
0x64..0xFE
Ignore
reserved
0xFF
Ignore
Last non zero level
Set last non zero
level
TABLE I
– Multilevel Switch Command Class Report
The Duration in Multilevel Switch Report advertises the time needed to reach the
Target Value at the actual transition rate.
TABLE J
–
Notification Command Class
Notification
Type
Event
Event/State
Parameter
Description
Heat Alarm
(0x04)
Overheat detected
(0x02)
–
Curtain motor is
overheat.
Power Manage-
ment (0x08)
Over-current detected
(0x06)
–
Curtain motor is
over-current.
System (0x09)
System hardware
failure (manufacturer
proprietary failure
code provided) [0x03]
0x01
Overtorque
0x02
Obstacle
0x03
Under voltage
0x04
Unresolvable
0x05
UART communi-
cation error
TABLE K
–
Configuration Command Class
33. Configuration of upper limit switch
Description
This parameter is used to save upper limit of the motor as the
actual position of the motor. Upper limit must be set before
controlling the motor to move to a specific position and only
when the motor stops.
Upper limit will not reset when device is removed from the
network.
Parameter size
1B
Default value
0
Available
values
0 – reset upper limit/upper limit not set
1 – set upper limit/upper limit set
34. Configuration of lower limit switch
Description
This parameter is used to save upper limit of the motor as the
actual position of the motor. Upper limit must be set before
controlling the motor to move to a specific position and only
when the motor stops.
Upper limit will not reset when device is removed from the
network.
Parameter size
1B
Default value
0
Available
values
0 – reset lower limit/lower limit not set
1 – set upper limit/upper limit set
39. Default motor cruise speed
Description
This parameter is used to configure the motor default cruise
speed.
Parameter size
4B
Default value
32
Available
values
16 ... 48 – rotations per minute
41. Acceleration configuration
Description
This parameter is used to configure how many rotations the
motor will accelerate to default cruise speed.
Parameter size
4B
Default value
0
Available
values
0 ... 30 – 0.1... 3 rotations