A.2 - Temporarily deactivating (and reactivating) motors you do not wish to program
NOTES AND WARNINGS
•
This procedure temporarily deactivates (for 5 minutes) only motors whose up and down limit switches have already been programmed.
A.2.1 - To temporarily deactivate motors you do not wish to program
1
2
end
ESC
=
5
sec
ESC
“
0
”
The system locks out only those motors whose lim-
it switches have already been programmed. It has
no effect on motors which have not yet been pro-
grammed.
The deactivation is temporary and lasts for 5
minutes.
Hold down the but-
ton and
release it after
5 sec-
onds
;
you will see a brief down
movement and a movement
which stops the awning at
the Up limit “0”.
For a period of 5 minutes, the locked out motors will
not respond to commands.
A.2.2 - To reactivate temporarily locked out motors
You can reactivate the motors in two ways
option –
A
1
end
option –
B
1
end
After 5 minutes
the
locked out motors are
automatically reactivat-
ed by the system.
During the 5 minute
period
the locked out
motors can be reacti-
vated at any time by the
user.
ESC
=
10
sec
ESC
Wait for
5 minutes
...
... the system will then
move the awning to
the mid position.
During the
5 minutes
, at
any time...
... hold down the
button and
release it after
10
seconds
;
the system will then
move the awning to
the mid position.
A
A.3 - MANUAL programming of the UP (“0”) and DOWN (“1”) limit switches
NOTES AND WARNINGS
• This procedure is obligatory only for awnings without a mechanical stop at the Up position.
•
This procedure can be used if the limit switches have been programmed using the semiautomatic procedure (A.4).
• After the limit positions have been programmed, the awning can be controlled by simply pressing the appropriate buttons on the control unit. The awning will move
between the positions set with procedures A.3.1 and A.3.2.
A.3.1 - To program the UP limit switch (“0”)
1
2
3
continues
(x
1
)
PRG
2
=
5
sec
2
Command
an UP
movement
Press and re-
lease the button (
1
time
);
count 2 movements.
Hold down the but-
ton and
release it after
5
seconds
;
count 2 movements.
Hold down the button and wait...
3
4
5
fine
“
0
”
↕
Finely adjust-
ing the posi-
tion of limit
switch “0”
“
0
”
=
5
sec
3
... release the button as soon as the awning
reaches
position “0”
(
UP
limit switch).
Press the buttons until you reach the desired position.
Alternatively
, for more accurate adjustment, run pro-
cedure B.1.
Hold down the
button and
release it after
5
seconds
;
count 3 movements.
A
7
– English
Содержание E Fit M 720
Страница 1: ...Nice KO E Fit M 720...
Страница 2: ...Machinery Directive III A 70 dB A 0 4 m 1 8 m 1 5 m 2 5m 1...
Страница 5: ...d M 10 mm e c a 4 f 1 2 g i h b 4...
Страница 17: ...Nice EN Instructions and warnings for installation and use Tubular Motor E Fit M 720...
Страница 21: ...d M 10 mm e c a 4 f 1 2 g i h b English 4...