Nice Apollo Titan 912L Скачать руководство пользователя страница 16

On the Slave operator, select Function -> Adv. Settings -> Remote Mst. Slv. 
Then select On -> Slave. The red LED associated with the Master/Slave 
connector will illuminate. 

identical open/close/stop functions in tandem with the Master gate operator. 

Programming the plug-in receiver and remote controls 

Nice 

Plug in Receiver: 

The Nice 433Plug-In Receiver provides up to 15 

built-in programming functions for adding or removing Nice wireless remote 

controls to/from a gate installation. The following procedures detail the steps 

to assign a remote control, add a new remote control, delete a single remote 

control, or remove all remote controls from the receiver memory. 

Programming the Nice 2-Button or 4-Button Remote Control with the 

Nice Plug-In Receiver. 

These procedures apply to the Nice wireless remote control. These procedures 
assign factory default controls automatically to the remote control. 

1.

 Have a functioning Nice 2-button or 4-button remote control with a battery 

installed prior to programming the remote control. 

2.

 Press and hold the button on the side of the Nice receiver until the led 

illuminates green on the Nice receiver, then release the button. 

3.

 Within 10 seconds, press and hold any key on the Nice remote control until 

the led in the Nice receiver blinks green 3 times, indicating that the Nice is 
programmed to control the receiver. 

4.

 After the led on the Nice receiver blinks green 3 times, another 10 second 

interval is started to program another Nice remote control if desired. Repeat 
step 3 to program the additional Nice remote control. Step 3 may be repeated 
as many times as necessary to program all available Nice remote controls. 

5.

 Verify that the Nice remote control(s) can control the gate by pressing one or 

more buttons individually on the remote control(s). 

Add new remote control to the Nice Plug-In Receiver 

A Nice remote control that has been programmed to control a Nice receiver 
may be used to create other Nice remote controls for the same receiver. This 
procedure needs to be performed within 10 to 20m (30 to 60 feet) of the Nice 
receiver, but the Nice receiver does not need to be physically accessed. 

1.

 Press and hold any button on the non programmed Nice remote control for 

at least 5 seconds, then release the button, taking note of the button that was 
pressed. 

2.

 Press the same button on the programmed Nice remote control three times. 

3.

 Press the same button in step 1 on the non programmed Nice remote control 

and release. 

4.

 It is recommended to test the new copy of the Nice remote control with the 

assigned gate controller. 

NOTE: This procedure will affect all Nice receivers within radio range. 

Deleting a Single Nice Remote Control from the Nice Plug-In Receiver 

Memory 

A Nice remote control that has been programmed to control a Nice receiver may 
be removed from the Nice receiver memory without affecting other assigned 
remote controls. This procedure needs to be performed at the Nice Plug-In 
Receiver with the affected Nice remote control.

1. 

Press and hold the button on the side of the Nice receiver until the led on 
the Nice receiver illuminates green and keep the button pressed. The led will 
illuminate after approximately 4 seconds. 

2. 

Press and hold any button on the Nice remote control until the led on the Nice 

3. 

Release the button on the side of the Nice receiver.

4.

 It is recommended to verify that the non programmed Nice remote control no 

longer controls the gate.

for each operator. See the “Programming Quick Start” procedures in this 
manual for a description of the gate learning process. 

On the Master operator, select Function -> Adv. Settings -> Remote Mst. Slv. 
Then select On -> Master. The red LED associated with the Master/Slave 
connector will illuminate.

6.3 - COMMUNICATION BUSES 

FIGURE 6.3 COMMUNICATION BUSES

OVIEW

Programming and diagnostic unit which connects directly to the gate 
controller and is part of the Nice “Opera” control system. The unit can be 
used in “stand-alone” mode via its front-panel keypad, or it may be accessed 
via a Bluetooth or cellular-enabled PDA, PC, or Smartphone when used with 
the 
O-View Software Suite. This unit, when matched with the OVIEW Bluetooth 
or 
GSM modules, enables remote control and management of the gate 
controller. Remote control functions include most of the programming 
functions that are available at the front panel LCD on the control board as 
well as software updates. 

OVBT:

 Bluetooth module for OVIEW and the “O-View Software Suite” 

application for PC, PDA, or Smartphone for localized wireless control of the 
gate controller. 

OVBTGSM:

  Combination  GSM  and  Bluetooth  module  that  plugs  into  the 

OVIEW  and  provides  cellular  phone  access  through  the  “O-View  Software 
Suite”  application  for  PC,  PDA,  or  Smartphone,  for  wireless  local,  national, 
and international controller of the gate controller. 

O-VIEW Software Suite:

 Provides desktop or Smartphone level control of 

as new versions of software are made available. 

BLUEBUS ACCESSORIES
MOTB:

 Moon Touch programmable keypad with secure codes (up to 9 

digits per code if required) to control gate opening and closing. Connects to 
the 2-wire BlueBUS connector with inexpensive unshielded twisted-pair wire. 

MOFB:

  Photocell  transmitter  and  receiver  pair  that  connects  to  the  2-wire 

BlueBUS connector with inexpensive unshielded twisted-pair wire and is a 

31.1 “General Entrapment Protection Provisions”. 

MASTER/SLAVE - ONLY USED IN 24V COMMERCIAL OPERATORS

The gate operator includes a two-pin connector designed to link two 
separate gate operators together as a Master/Slave pair. The Master/Slave 

unshielded  twisted-pair  wire  (Max.100  ft.).  All  entrapment  sensors,  switch 
inputs,  receiver  controls,  and  outputs  must  be  wired  to  the  gate  operator 
designated as the “Master”. The following procedure outlines the process for 

13

Содержание Titan 912L

Страница 1: ...ing Gate Operator Nice Gate Operators Titan 912L The Titan 912L Gate Operator is intended for use with vehicular swing gates The Titan 912L Gate Operator can be used in Class I Class II and Class III...

Страница 2: ...TABLE OF CONTENTS...

Страница 3: ...tor Motor Leads 9 Figure 5 16 Gate Bracket Mounting 9 Figure 5 15 Limit And Motor Connection To The Board 10 Figure 5 17 Limit Switch Adjustment 10 Figure 5 19 Learning Mode Open Limit 10 Figure 5 20...

Страница 4: ...icular Gate Operator Class III A vehicular gate operator or system intended for use in an industrial location loading dock area or other location not intended to service the general public 912L The Ti...

Страница 5: ...rements countles s AUTOMATIC GATES ARE NOT FOR PEDESTRIANS 3 SAFETY AND CAUTIONS WARNING IMPORTANT SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF INJURY OR DEATH READ AND FOLLOW ALL INSTRUCTIONS 3...

Страница 6: ...d should 3 3 Gate system safety devices 3 4 Infrared beams and warning signs 3 5 Establish the location 3 6 Read and follow all instructions 3 7 Keep children away 3 8 Test the gate system release 3 9...

Страница 7: ...fic to the appli cation in question with absolute safety in all considerations 4 3 35 Never mount any device that operates the gate opener where the user can reach around over or through the fate to o...

Страница 8: ...rcuit board is powered Doing so may damage the board beyond repair PULL TO OPEN INSTALLATION PIVOT ARM INSTALLATION Location of Pivot Point The following instructions provide up to 105 of swing Measur...

Страница 9: ...n from the center of pivot of the gate hinge Vertical Position Of Pivot Arm DIRECTION OF OPENING GATES CLOSED HINGE POST HINGE POST LEFT HAND SWING RIGHT HAND SWING TOP VIEW 6 11 6 11 The top edge of...

Страница 10: ...the front Do not use any battery with side terminals FIGURE 5 6 CONTROL BOX MOUNTING FIGURE 5 7 INCOMING POWER WIRING 5 5 Incoming power wiring Power input connections should be wired as follows Sola...

Страница 11: ...lue Encoder Power Green Yellow Blue Orange White Limits and Encoder White Close limit Orange Open Limit Green Limit Common Yellow Encoder Signal Blue Encoder Power Green Yellow Blue White Orange With...

Страница 12: ...ves in opposite direction from what is expected reverse the motor power lead wiring Black Red Motor 1 Motor 2 Install the 5 and 3 pin connector for motor 1 into the connection labeled Motor 1 on the c...

Страница 13: ...N press the OK button select Swing press OK select LIGHT AVERAGE or HEAVY depending on the gate and press OK a last time If done correctly the display should read LEARN with ENTER flashing below 13 Tu...

Страница 14: ...afety devices and start the learning sequence The gate will open partially then stop This is being done so that the control board can sense the type and operational condition of the drive motor The ga...

Страница 15: ...Momentarily shorting the digital input to GND opens the gate to the full open position with the subsequent auto close feature enabled Guard Station Stop 35 Dry contact input Normally Closed for a guar...

Страница 16: ...ice receiver may be removed from the Nice receiver memory without affecting other assigned remote controls This procedure needs to be performed at the Nice Plug In Receiver with the affected Nice remo...

Страница 17: ...iring system GREEN WIRE This ground connection will prevent dangerous currents from appearing on the metal control box the actuator or the gate itself DO NOT WIRE AC MAINS POWER TO THE METAL CONTROL B...

Страница 18: ...ng gate upon sensing an exiting vehicle 9 2 MAGNETIC LOCK CONNECTION 7 NC 8 Com Common 9 NO 10 GND 11 V Voltage is determined by incoming power supply This connection is used to install the magnetic l...

Страница 19: ...Common Ground FIGURE 10 1 RADIO RECEIVER 16 Damaged discolored or overheated equipment connections wiring bearing caps and installations Excessive heat or discoloration at high current carrying connec...

Страница 20: ...apment Protection Inputs Typical Installation Diagram Utilizing Photocells Loop Safety Loop Safety Loop Shadow Loop Exit 4 Min from closed gate 4 Min from closed gate 4 Min from open gate Photo 2 Phot...

Страница 21: ...als are not obstructed or impeded by building structures natural landscaping or similar obstruction DURING INSTALLATION DISCONNECT POWER at the control panel before making any electric service power c...

Страница 22: ...d remove key 3 Replace rubber key cover 4 Operator is now in Automatic Mode Manual Release Disengage FIGURE 13 3 MANUAL RELEASE DISABLE 1 Lift rubber key cover and insert key into lock and rotate 90 c...

Страница 23: ...f sudden impact force to the moving gate on a scale of 1 to 10 1 being most sensitive ESC Exit the FORCE menu 15 2 SPEED Max Sets the limit of maximum allowed gate speed on a scale of 20 to 100 20 bei...

Страница 24: ...r as required by the customer s installation requirements Set Language English Spanish French Set clock 12H 24H Set LCD Contrast Direction Motor Changes main motor direction Can only be performed in l...