11.5 - Function
Learn:
Puts the gate operator into learning mode for a Swing or Slide gate and Blue BUS
peripherals. Learning mode for a Swing or Slide style gate involves selecting the gate type
(Light, Average, Heavy), then fully opening and closing the gate to sense the limits. Select-
ing the gate type selects precalculated values for the FORCE, SPEED, and ACCELERA-
TION settings. Learning the Blue BUS peripherals enables the gate operator to discover
and integrate accessory devices like Blue BUS access control and safety devices.
Positions:
Configures the points in the gate open, close, and partial cycles at which decel-
eration occurs.
Slow Down –
Open: Sets the point in the % of gate opening when the gate begins de-
celeration to the fully open position.
Slow Down –
Close: Sets the % of gate opening when the gate begins deceleration to
the fully close position.
Partial:
Sets the point in the % of gate opening when the gate begins deceleration to
the Partial open position.
Auxiliary Inputs:
Auxiliary inputs IN AUX1 (16) and IN AUX2 (18) can be programmed
with one of the following options:
• No program No Function used
• OPEN the Gate
• CLOSE the Gate
• STEP Cycling Step (Open-Stop-Close-Stop)
• PARTIAL opening
• PARTIAL 1 Partial Opening 1 (open one leaf in dual gate applications)
• STOP the gate and Auto-closing
• HOLD TO OPEN Input must be maintain active for Opening
• HOLD TO CLOSE Input must be maintain active for Closing
• FIRE Reset Hard Shut Down and Open the Gate
• TIMER 1 Start Count Down TIMER1
• TIMER 2 Start Count Down TIMER2
• PHOTO Photocell PHOTO input: reverse to opening when closing
• PHOTO1 Photocell PHOTO1 input: Stop Gate when activated
• PHOTO2 Photocell PHOTO2 input: reverse to closing when opening
• SHADOW Loop input: prevent closing gate when completely open
• LOCK system from other command (only STEP H overrides the Block)
• UNLOCK Un-lock the system if locked
• OPEN and LOCK Open the Gate and inhibit further commands (except STEP H)
• CLOSE and LOCK Close the Gate and inhibit further commands (except STEP H)
• OPEN and UNLOCK Open the Gate and un-inhibit further commands
• CLOSE and UNLOCK Close the Gate and un-inhibit further commands
• STEP H Command high priority Step cycling (open-stop-close-stop
Auxiliary Outputs:
Auxiliary outputs OUT AUX1 (1,2,3,) and OUT AUX2
(4,5,6,) can be programmed with one of the following options:
NO PROGRAM Output not used
OPEN Output is activated when Gate is open
CLOSE Output is activated when Gate is closed
MOVING Output is activated when Gate is moving
TIMER 1 Output is activated when TIMER1 is counting down
TIMER 2 Output is activated when TIMER2 is counting down
LOCK Output is activated when the Gate is locked
MAINT Output is activated when the maintenance cycle counter decrements to 0