
INSTALLATION
The accumulator tank must be installed in an upright
position. The four feet are vertically adjustable.
All connections (including connections or holes that are
not used) must be insulated to minimise energy losses.
DOCKINGS
NOTE
These are outline diagrams. Actual installations
must be planned according to applicable
standards.
Volume increase as well as reduction of heat spikes
A UKV 500 is installed as a volume increaser in those cases where the system volume in the climate system is
below the minimum recommended volume for the heat pump.
Volume and flow increaser and reduction in heat spikes
A UKV 500 is installed as a volume and flow increaser in those cases where the system volume in the climate
system is below the minimum recommended volume for the heat pump and/or the flow is restricted without
control.
19
UKV 500 | GB
Содержание UKV 500
Страница 2: ......