background image

LEK

3

2

QM20

Jetzt kann ein Wechsel der Umwälz-
pumpe erfolgen.

3.

LEK

XJ1

Trennen Sie das Netzkabel vom
Anschluss XJ1.

4.

| DE

28

Содержание SPLIT

Страница 1: ...ION Utbyte av cirkulationspump i SPLIT Xylem till WILO GB SERVICE INSTRUCTION Replacement of the circulation pump in SPLIT Xylem to WILO DE SERVICEANLEITUNG Wechsel des Umw lzpumpensatzes in SPLIT Xyl...

Страница 2: ......

Страница 3: ...PARA 7 0 PWM 1 i SPLIT inomhusmodul L s igenom hela instruktionen innan arbetet p b rjas Komponenter 724 028 Cirkulationspumpskit reservdel 218 810 1 Cirkulationspump 033 460 2 Packning 218 785 1 Kraf...

Страница 4: ...i inomhusmodul Hydro Unit Demontering av luckor VARNING G r aggregatet sp nningsl st innan arbetet p b rjas Elistallation samt service ska ske under verin seende av beh rig elinstallat r LEK LEK 1 2 7...

Страница 5: ...t trycket via s kerhetsventilen St lldon QM31 ska vara i st ngt horisontellt l ge LEK HQ1 QM31 St ng av klimatsystemet genom att st nga avst ngningsventilen QM31 och ventilen vid partikelfilt ret HQ1...

Страница 6: ...LEK XJ1 Fr nkoppla str mkabeln p termi nal XJ1 4 X1 1 X1 2 Fr nkoppla PWM signalkabeln fr n terminal X1 1 och X1 2 p kommu nikationskortet AA23 5 SE 6...

Страница 7: ...slut ningspunkterna B 7a Med energim tare Lossa den vre muttern A och avl gsna r ret ge nom att att lossa r ranslutningen till fl desm taren C 7b Avl gsna cirkulationspumpen och s tt tillbaka topplock...

Страница 8: ...LEK 130 165 15 0 90 60 22 0 Mor a kni v UN Demontera topplocket 10 SE 8...

Страница 9: ...med lim OBS F lj instruk tionerna p limf rpackningen B rja med den nedre EPP detaljen 225 624 L gg en limstr ng l ngs baksidans ytterkant S tt EEP detal jen p plats justera i h jd med be fintlig EPP V...

Страница 10: ...kopplas brun kabel signal in p X1 1 Bl kabel kopplas in p X1 2 LEK LEK 2 1 1 Byt packningarna anv nd de som bifogats reservdelspumpen Monterareservdelspumpen Obser vera att utlopps ppningen pekar ned...

Страница 11: ...mtrycket p mano metern BP5 Fyll p systemet med vatten om det beh vs Klimatsystemets s kerhetsventil FL2 skall vara helt t t 6 LEK QM20 QM24 QM60 Avluftasystemetviaavluftningsven tilerna QM20 QM24 och...

Страница 12: ...allh ljet till kommunikationskortet AA23 Fix era med buntband 9 10 AnslutPWM kabelntillkommunika tionskortet AA23 terminal X1 Brun ledare PWM till position 1 Bl ledare PWM GND till posi tion 2 10 LEK...

Страница 13: ...S F lj instruktionerna p limf rpackningen Placera den vre EPP detaljen 225 623 enligt bild 12 UN termontera topplocket 13 Anslut str mmen och starta upp v rmepumpsystemet 14 Avlufta igen om det beh vs...

Страница 14: ...PARA 7 0 PWM 1 in SPLIT indoor modules Read all of the instructions before starting work Components 724 028 Circulation pump kit spare part 218 810 1 Circulation pump 033 460 2 Gasket 218 785 1 Power...

Страница 15: ...r module Hydro Unit Removing the covers WARNING Cut the power to the unit before starting work Electrical installation and service must be car ried out under the supervision of a qualified electrician...

Страница 16: ...e the pressure via the safety valve Actuator QM31 must be in the closed horizontal position LEK HQ1 QM31 Switch off the climate system by closing the shut off valve QM31 and the valve at the particle...

Страница 17: ...LEK XJ1 Disconnect the power cable from terminal XJ1 4 X1 1 X1 2 Disconnect the PWM signal cable from terminal X1 1 and X1 2 on the communication board AA23 5 17 GB...

Страница 18: ...7a With energy meter Slacken off the upper nut A and remove the pipe by detaching the pipe connec tion to the flow meter C 7b Remove the circulation pump and replace the top cover 8 Start by cutting o...

Страница 19: ...LEK 130 165 15 0 90 60 22 0 Mor a kni v UN Remove the top cover 10 19 GB...

Страница 20: ...n the adhesive pack aging Start with the lower EPP compon ent 225 624 Apply a bead of ad hesive along the outer edge of the rear side Place the EPP component in position align vertically with the exis...

Страница 21: ...AA23 the brown cable signal is connected to X1 1 The blue cable is connected to X1 2 LEK LEK 2 1 1 Replace the gaskets use the ones supplied with the replacement pump Install the replacement pump Not...

Страница 22: ...n the manometer BP5 Top up the sys tem with water if necessary The climate system s safety valve FL2 must be completely sealed 6 LEK QM20 QM24 QM60 Vent the system via the vent valves QM20 QM24 and QM...

Страница 23: ...housing to the communication board AA23 Secure using cable ties 9 10 Connect the PWM cable to the communication board AA23 ter minal X1 Brown core PWM to terminal 1 Blue cable PWM GND to termin al 2...

Страница 24: ...3 Note Follow the instructions on the adhesive packaging Position the upper EPP component 225 623 as illustrated 12 UN Replace the top cover 13 Connect the power and start the heat pump system 14 Vent...

Страница 25: ...Inneneinheiten beschrieben Lesen Sie vor Beginn der Arbeiten die gesamte Anleitung vollst ndig durch Komponenten 724 028 Umw lzpumpensatz Ersatzteil 218 810 1 Umw lzpumpe 033 460 2 Dichtungen 218 785...

Страница 26: ...kungen demontieren ACHTUNG Unterbrechen Sie vor Beginn der Arbeiten die Spannungszufuhr zum Aggregat Elektrische Installation sowie Servicearbeiten m ssen unter Aufsicht eines ausgebildeten Elektroins...

Страница 27: ...XL2 Lassen Sie den Druck ber das Sicherheitsventil ab Stellantrieb QM31 muss sich in der geschlosse nen horizontalen Stellung befinden LEK HQ1 QM31 Schalten Sie das Klimatisierungssys tem aus indem S...

Страница 28: ...LE K 3 2 QM20 JetztkanneinWechselderUmw lz pumpe erfolgen 3 LEK XJ1 Trennen Sie das Netzkabel vom Anschluss XJ1 4 DE 28...

Страница 29: ...X1 1 X1 2 L senSiedasPWM Signalkabelvon Anschluss X1 1 und X1 2 an der Kommunikationsplatine AA23 5 LE K 6 Demontieren Sie die Umw lzpum pe Beginnen Sie mit dem unteren Rohranschluss 6 29 DE...

Страница 30: ...ndem Sie den Rohranschluss f r den Volumen strommesser C l sen 7b Entfernen Sie die Umw lzpumpe und bringen Sie die obere Abde ckung wieder an 8 Schneiden Sie zun chst das EPP im gekennzeichneten Bere...

Страница 31: ...n Sie den Anweisungen auf der Kleb stoffverpackung Beginnen Sie mit dem unteren EPP Teil 225 624 Bringen Sie einen Klebstoffstrang entlang der u e ren Hinterkante an Bringen Sie das EPP Teil an Passen...

Страница 32: ...l Signal mit X1 1 Verbinden Sie das blaue Kabel mit X1 2 LEK LEK 2 1 1 Ersetzen Sie die Dichtungen durch die Dichtungen im Lieferumfang der Ersatzteilpumpe Montieren Sie die Ersatzteilpumpe Beachten S...

Страница 33: ...Fallserforder lich bef llen Sie das System mit Wasser Das Sicherheitsventil des Klimatisie rungssystems FL2 muss dicht schlie en 6 LEK QM20 QM24 QM60 Entl ften Sie das System ber die Entl ftungsventi...

Страница 34: ...ommuni kationsplatine AA23 Nutzen Sie zur Befestigung Kabelbinder 9 10 Verbinden Sie das PWM Kabel mit der Kommunikationsplatine AA23 Anschluss X1 Brauner Leiter PWM an Position 1 Blauer Leiter PWM GN...

Страница 35: ...rpackung Positionieren Sie das obere EPP Teil 225 623 gem Abbildung 12 UN Bringen Sie die obere Abdeckung wieder an 13 Schlie en Sie die Stromversorgung an und starten Sie das W rmepum pensystem 14 F...

Страница 36: ......

Страница 37: ......

Страница 38: ......

Страница 39: ......

Страница 40: ...WS name Gemensamt WS version a460 WS release date 2018 01 17 13 30 Publish date 2018 01 29 07 30 431304...

Отзывы: