NOTE
Telephone numbers provided must be able to
receive SMS messages.
Contact with NIBE SMS 40
NIBE SMS 40 sends an SMS in the event of a power cut, when the climate unit starts after a power cut and in
the event of a constant alarm. These messages are only sent to the alarm receiver (menu 4.1.4, menu 5.3.5 if
your climate unit has software version 2041 or earlier).
Caution
The command that is sent to/from NIBE SMS 40 must always be written as
one
word, for example
"?solar".
SMS COMMANDS FOR OPERATING INFORMATION
The following command can be sent to NIBE SMS 40 to obtain operating information about your climate unit:
Description
Answer
Command
Operating status
opmode: auto/add. heat only
?status
Temperature (offsetting the heat curve in systems without room
sensors)
reg1: -10–10
Temperature (offsetting heat curve in systems without room sensor),
climate systems 2
1)
reg2: -10–10
Temperature (offsetting heat curve in systems without room sensor),
climate systems 3
1)
reg3: -10–10
Temperature (offsetting heat curve in systems without room sensor),
climate systems 4
1)
reg4: -10–10
Temperature (setting the room temperature in systems with room
sensors)
roomt1: 5–30
Temperature (setting the room temperature in systems with room
sensors), climate system 2
1)
roomt2: 5–30
Temperature (setting the room temperature in systems with room
sensors), climate system 3
1)
roomt3: 5–30
Temperature (setting the room temperature in systems with room
sensors), climate system 4
1)
roomt4: 5–30
Temporary lux (hot water)
tluxhw: on/off
Fan speed. 0 = normal fan speed
2), 3+1), 4+1)
vent: 0/1/2/3/4
Holiday setting
hol: on/off
Compressor status
2), 3)
status: runs/off
?comp
Number of compressor starts
2), 3)
number of starts: nn
Total run time compressor and immersion heater?
2), 3)
total operating time: nn
Total run time hot water
2), 3)
- of which hot water: nn
Compressor status per cooling module (EP14 respectively EP15)
4)
status: runs/off
?compm/?comps1
– ?comps8
Compressor status =through outdoor section (EB10X)
7)
Number of compressor starts per cooling module (EP14 respectively
EP15)
4), 7)
number of starts: nn
Total run time, compressor per cooling module (EP14 respectively
EP15)
4), 7)
total operating time: nn
Total run time, hot water per cooling module (EP14 respectively
EP15)
4), 7)
- of which hot water: nn
Number of compressors that produce heat
4), 7)
heating: nn
?acomp
Number of compressors that charge hot water
4), 7)
hot water: nn
Number of compressors that charge pool 1
4+1), 7+1)
pool: nn
Number of compressors that charge pool 2
4+1), 7+1)
pool 2: nn
NIBE SMS 40 | GB