Connection to indoor
module and air/water
heat pump
Heating medium connection, supply (XL8) and heating
medium connection, return (XL9) are connected to the
return line between the indoor module and the air/water
heat pump. The particle filter must be installed before
S135 to prevent dirt from depositing in S135. Install the
shut-off valves outside S135 to facilitate any future ser-
vicing.
-AZ1-QM2
-AZ1-QM1
-AZ1-HQ1
-AZ1-GP12
-AZ1
-AZ1
Installation exhaust air
S135 must be connected according to the instructions
in this manual.
Installation must be carried out in accordance with cur-
rent standards and directives.
EXHAUST AIR
Connecting the exhaust air
The heat pump uses the heat that is in the building's
ventilation air to heat the building and the hot water at
the same time that the house is ventilated.
The hot air is transferred from the rooms to the heat
pump via the exhaust air module.
NOTE
An air filter (HQ12) (enclosed), minimum classi-
fication G2, is required on the exhaust air duct
for this connection. The filter must be cleaned
regularly.
Caution
Noise from the fan can be transferred via the
ventilation ducts.
15
Chapter 4 | Pipe and air connections
NIBE S135