SYSTEM DIAGRAM
S135 is an exhaust air module.
When the air passes through the evaporator, the refri-
gerant evaporates because of its low boiling point. In
this way the energy in the air is transferred to the refri-
gerant.
The refrigerant is then compressed in a compressor,
causing the temperature to rise considerably.
The warm refrigerant is led to the condenser. Here, the
refrigerant gives off its energy to the hot water,
whereupon the refrigerant changes state from gas to
liquid.
The refrigerant then goes via filters to the expansion
valve, where the pressure and temperature are reduced.
The refrigerant has now completed its circulation and
returns to the evaporator.
XL8
XL9
Heating medium connection, supply
XL8
Heating medium connection, return
XL9
Caution
This is a principle of operation, differences may
occur in the installation in question.
Dimensions and pipe
connections
460
135
1
1
5
300
45
475
XL8
WM2
XL9
PIPE DIMENSIONS
Connection
22
(mm)
XL8 Heating medium connection, supply ext
Ø
22
(mm)
XL9 Heating medium connection, return ext
Ø
20
(mm)
WM2 Overflow water discharge int Ø
13
Chapter 4 | Pipe and air connections