The number of steps the value has to be changed in
order to achieve a one degree change to the indoor
temperature depends on the climate system. One step
is usually enough, but in some cases several steps may
be required.
Set the desired value. The new value is shown on the
right-hand side of the symbol on home screen heating.
Caution
An increase in the room temperature can be
slowed by the thermostats for the radiators or
under floor heating. Therefore, open the ther-
mostats fully, except in those rooms where a
cooler temperature is required, e.g. bedrooms.
TIP
Wait 24 hours before making a new setting,
so that the room temperature has time to sta-
bilise.
If it is cold outdoors and the room temperature
is too low, increase the curve slope in menu
1.30.1 by one increment.
If it is cold outdoors and the room temperature
is too high, reduce the curve slope in menu
1.30.1 by one increment.
If it is warm outdoors and the room temperat-
ure is too low, increase the value in menu 1.1.1
by one increment.
If it is warm outdoors and the room temperat-
ure is too high, reduce the value in menu 1.1.1
by one increment.
MENU 1.3 - ROOM SENSOR SETTINGS
Name room sensor
Setting range: a-z
Control room sensor
Setting range: on/off
Coefficient of performance system
Setting range: 0.0 - 6.0
Activate room sensors to control the room temperature
here.
You can connect up to four room sensors to each cli-
mate system, and you can give each sensor a unique
name.
The sensor in each climate system that is furthest from
the set temperature has control; S1255 tries to keep
the temperature up in the room whose sensor is furthest
from the set value.
Caution
A slow heating system such as underfloor
heating may be inappropriate for controlling
with room sensors.
Factor system
You can also set a factor that determines by how much
the difference between the desired and current room
temperature will affect the supply temperature to the
climate system. A higher value gives a greater and faster
change in the heating curve's set offset.
Caution
Too high a set value for "factor system" can
result in an uneven room temperature.
If several climate systems are installed the above set-
tings can be made for the relevant systems.
MENU 1.5 - CLIMATE SYSTEM NAME
You can give the installation's climate system a name
here.
MENU 1.30 - ADVANCED
Menu
advanced
is intended for the advanced user. This
menu has several sub-menus.
Curve, heating
Setting the heating curve slope.
External adjustment
Setting the heating curve offset
when an external contact is connected.
Lowest supply heating
Setting minimum permitted
supply temperature during heating operation.
Highest supply heating
Setting maximum permitted
supply temperature for the climate system.
Own curve
You can create your own heating curve
here, if there are special requirements, by setting the
desired supply temperatures for different outdoor tem-
peratures.
Point offset
Select a change in the heating curve at a
certain outdoor temperature here. One step is usually
enough to change the room temperature by one degree,
but in some cases several steps may be required.
MENU 1.30.1 - CURVE, HEATING
Curve, heating
Setting range: 0 - 15,0
In menu "Curve, heating" you can view the heating curve
for your house. The task of the heating curve is to
provide an even indoor temperature, regardless of the
outdoor temperature. It is from this heating curve that
S1255 determines the temperature of the water to the
climate system, the supply temperature, and therefore
NIBE S1255
Chapter 9 | Control - Menus