Electrical connection
Note!
The maximum output that can be connected to the
heat pump is 200 W. If a longer heating coil than the sup-
plied coil is required, it must have an external power supply
with earth circuit-breaker.
FIGHTER 2020/F2025
1.
Use the safety switch to cut the incoming supply.
2.
Open the plastic cover and the junction box on the heat
pump.
3.
Pull up the cable from the heating coil through the cable
gland and continue to the junction box on FIGHTER
2020/F2025.
4.
Connect the conductors from the heating coil to termin-
als 5 and 6 on terminal block X11 in FIGHTER
2020/F2025.
5.
Close the junction box and the cover on the heat pump.
X11
FIGHTER 2005/2010
1.
Use the safety switch to cut the incoming supply.
2.
Open the plastic cover and the junction box on the heat
pump.
3.
Pull up the cable from the heating coil through the cable
gland and continue to the junction box on FIGHTER
2005/2010.
4.
Connect the conductors from the heating coil to termin-
als 9 and 10 on terminal block X13 in FIGHTER
2005/2010.
5.
Close the junction box and the cover on the heat pump.
LEK
X13
Maintenance
The trough and drain pipe may require cleaning from leaves
or similar during the year.
Cleaning
1.
Use the safety switch to cut the incoming supply.
2.
Reverse the order of installation to remove the trough.
I.e. first detach the left and then the right front edge.
Keep in position at the rear edge without stretching the
power cable.
3.
Clean trough and drain.
4.
Reinstall the trough.
5.
Switch on the safety switch again.
KVT 10