List of components

  1  Immersion heater 8 kW
  2  Relay card, ventilation control
  3  Operating thermostat, backup heating
  4  Supply air sensor
  5  Venting screw, supply air battery
  6  Temperature limiter, immersion heater
  7   Miniature circuit-breaker for the circulation pump,  

automatic heating control system and the compressor

  8  Switch, position 0 -1 - 
  9  Terminal block, power supply
  10  Contactor step 1
  11  Terminal block, docking
  12  Rating plate
  14  Terminal block
  15  Outside sensor
  16  Circulation pump
  17  Air screw, circulation pump
  18  Pushbutton, Extra hot water
  19  Shunt motor with handwheel
  20  Connector, exhaust air fan
  21  Connector, supply air fan
  22  Terminal block, fan speed
  25  Push button for the operating mode
  26  Motor protection, compressor
  27  Compressor
  28  Operating capacitor, compressor 
  29  Relay card with power supply unit
  30  Indicator lamp, Compressor
  31  Indicator lamp, Defrosting
  32  Indicator lamp, Immersion heater
  33  High pressure pressostat
  34  Microprocessor card

  35  Capacity setting, circulation pump
  36  Fan, exhaust air
  37  Knob, Heating curve selection
  38  Knob, Offset heating curve
  39  Pushbutton, Channel selection
  40  Numerical display with control card behind
  41  Low pressure pressostat
  42  Pressure gauge, boiler
  43  Shunt valve
  44   Shutoff valve, pump and supply radiator circuit
  46  Filler valve, water heater
  47  Safety valve, water heater
  48  Expansion valve (hidden)
  50  Shutoff valve, return line radiator circuit
  51  Drain valve, heating system
  52  Safety valve, heating system
  53  Vacuum valve (hidden)
  54  Fan transformer
  55  Control lamp, immersion heater
  56  Indicator lamp, Circulation pump
  57  Start condenser, exhaust air fan
  58  Strain relief
  59  Strain relief, supply cable
  60  Fan, supply air
  61  Supply air battery
  62  Evaporator
  63  Air filter, exhaust air (Filter type G2)
  64  Drawing magnet, supply air damper
  65  Drying filter with tank
  66  Air filter, supply air (Filter type G2)
  67  Contactor, step 2
  68  Docking pipe 

For the Installer

31

 

   

Connection 

 Setting out dimensions

 

 

 

  

C

  70  Supply line, radiator circuit (angled 45° back/left)  .....................  Compression ring Ø 22 mm ..   30  ....... 465 ........   90
  71  Return line, radiator circuit  .........................................................  Compression ring Ø 22 mm .. 130  ....... 465 .......  190
  72  Start capacitor, supply air fan
  73  Cold water connection  ...............................................................  Compression ring Ø 22 mm .. 180  ....... 465 .......  290
  74  Hot water outlet from water heater  ............................................  Compression ring Ø 22 mm .. 290  ....... 465 .......  345
  76  Filter cover, exhaust air
  77  Side access panel, valve coupling
  78  Filter cover, supply air
  80  Drain connection, heating system  .............................................  R 15 male
  81  Trim valve, supply air battery
  82  Electrical supply for load monitor (accessories)
  84  Ventilation opening
  85  Expansion vessel
  86  Temperature sensor, evaporator (hidden)
  87  Temperature sensor, extract air (hidden)
  88  Temperature sensor, immersion heater operation
  89  Temperature sensor, supply line
  90  Ventilation connection exhaust air  .............................................  Ø 125 mm  .......................... 2095  ....... 295 .......  160
  91  Ventilation connection extract air  ...............................................  Ø 125 mm  .......................... 2095  ....... 295 .......  485
  92  Ventilation connection, outdoor air .............................................  Ø 125 mm ........................... 2140  ....... 190 .......  435
  93  Ventilation connection, supply air ...............................................  Ø 125 mm ........................... 2140  ....... 470 .......  350
  94  Temperature sensor, compressor operation
  95  Overflow pipe, safety valve water heater
  96  Overflow pipe, safety valve heating
  97  Condensation water outlet, fan box
  98  Overflow water discharge  ..........................................................  PVC-pipe Ø 32 mm (outside diameter)
  99  Collection funnel, waste water
103  Serial number sign
106  Expansion vessel, tap water
107  Switch, “Fan speed”
108  Tundish from safety valve
109  Tundish from temperature relief valve
115  Terminal block
145  Temperature and pressure valve

FIGHTER 410P

147  Filling hose
148  Pressure reduction valve
149  Connection for flexible hose to CW-side
150  Connection for flexible hose to heating-side
151  Filling valve, heating system (CW-side)
152  Filling valve, heating system (heating-side)
169  Temperature limiter, compressor

Содержание FIGHTER 410P

Страница 1: ...INSTALLATION AND MAINTENANCE INSTRUCTION FIGHTER 410P 230V MOS GB 0823 2 FIGHTER 410P 511379 L E K...

Страница 2: ...LEK LEK 1 2 LEK LEK 1 3 4 5...

Страница 3: ...trol system Heating curve offset 2 22 Heating curve offset 0 22 Heating curve offset 2 22 Setting with diagrams 22 Service Opening the front panel 23 Refrigerant system 23 Channel description 23 Deali...

Страница 4: ...sure 16 bar Immersion heater R50 8000W 230 V Operating pressure tap water 6 bar Expansion vessel tap water charge pressure 3 5 bar Expansion vessel heating water charge pressure 0 5 bar Pressure reduc...

Страница 5: ...valve where the pressure and temperature are further reduced The refrigerant has now completed its circulation and returns to the evaporator A frost protection damper precedes the supply air side s h...

Страница 6: ...Upper visible part of the front panel Numerical display Art nr 611822 2 1 bar 3 0 4 2 1 bar 3 0 4 2 1 bar 3 0 4 41 19 2 83 90 5 111 98 6 523 15 70 5 135 3 Switch Pressure gauge Indicator lamps Extra...

Страница 7: ...tandby mode to normal mode 1 the numerical display can remain dimmed for a brief period This can also occur at extremely low outdoor tem peratures Extra hot water Pressing the Extra hot water button r...

Страница 8: ...1 bar 3 0 4 111 523 Front panel FIGHTER 410P For Home Owners 6 Lower hidden part of the front panel Indicator lamps Heating curve selection Operating mode Channel selection I H J G L Miniature circuit...

Страница 9: ...always shows channel 1 When you have browsed through the channels channel 1 returns after a while Heating curve selection Use the Heating curve selection knob to set the automatic heating control syst...

Страница 10: ...eratures have time to stabilise Readjustment of basic settings Cold weather conditions If the room temperature is low increase the heating curve selection setting by one step If the room temperature i...

Страница 11: ...Assembly takes place in the reverse order Every third month a reminder for cleaning the filter is shown in the display as A 01 Note that the time will be set to zero by setting the switch to 0 Cleani...

Страница 12: ...eck one valve at a time as follows Open the valve Check that water flows through the valve Close the valve The heating system may need to be refilled after checking the safety valve 52 see the section...

Страница 13: ...nd the highest radiator is 5 metres see figure If the standard initial pressure in the pressure vessel is not high enough it can be increased by adding air via the valve in the expansion vessel The in...

Страница 14: ...Discharge pipes from tundishes shall have av vertical section of pipe at least 300 mm long before any elbows or bends in the pipework See following picture General If the vertical distance 300 mm is...

Страница 15: ...kapacitet Fl de Tillg ngligt tryck kPa Internt tryckfall i panna inklusive armatur Tillg nglig pumpkapacitet pannans interntryckfall fr ndraget kPa 4 l h P 5 6 3 2 wg 10 200 0 0 20 400 30 600 40 800 5...

Страница 16: ...e supply air battery is connected in parallel with the radiator circuit and heats the house s supply air The addi tional output is determined according to the diagram The water flow through the supply...

Страница 17: ...ould not be changed In position A reduced position a low exhaust air respective supply air flow should be obtained How low is determined in each specific case NOTE The exhaust air flow must never drop...

Страница 18: ...rthed This is done by making a sound electrical connection to the four ventilation ducts using the four earthing cables supplied The cables must then be connected to the earthing studs on top of the t...

Страница 19: ...nging the output Connection Power rating as set at the factory NOTE Reset the temperature limiter it may have tripped during transport NOTE The switch 8 must not be moved from 0 until the boiler has b...

Страница 20: ...ion B normal White cable 099 Exhaust air fan position C forced NOTE The same outlet must never be used for both fans Setting the fan capacity black white black white black white Normally the immersion...

Страница 21: ...effektvakt 14 Rundstyrning RS och effektvakt EV Brytande kontaktfunktion RS EV EV RS SKYDDSKLENSP NNING SELV 1 2 3 4 5 6 7 8 ROMF LER RUNDSTYRING B R ER A B UTEF LER A Rundstyring eller belastningsvak...

Страница 22: ...en it is opened for the first time Vent the FIGHTER through the safety valve 52 Other heating systems are vented using their respective venting screws Keep topping up and venting until all air has bee...

Страница 23: ...in valve 51 using an R15 1 2 hose coupling Remove the cover 80 from the valve Now screw on the hose cou pling and open valve 51 Open safety valve 52 to let air into the system Draining the heating sys...

Страница 24: ...RVA 2 V RMEKURVA 30 40 50 60 70 C FRAMLEDNINGSTEMPERATUR 40 C UTETEMPERATUR 10 0 10 20 30 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1514 13 12 11 10 8 7 6 5 4 3 2 1 40 C UTETEMPERATUR 10 0 10 5 5 30 40 50 6...

Страница 25: ...ual value 03 Outside temperature Actual value 04 Evaporation temperature Actual value 05 Extract air temperature Actual value 06 Curve slope Heating curve selection 07 Offset Heating curve offset 08 T...

Страница 26: ...ion of a qualified installer Wrong operating mode selected with button 25 Closed or throttled filler valve 46 on the water h e a t e r Low temperature or a lack of hot water Circuit or main MCB trippe...

Страница 27: ...efrosting is a sign of clogged ventilation or dirty filters See the sec tion Maintenance routines Cleaning the air filter Indications on the display NOTE This fault state must not be repeatedly reset...

Страница 28: ...the fan this may need cleaning Contact your installer Cleaning the fan Luftningsskruv 16 Luftningsskruv 16 LEK LEK G RU N DFOS Type UPS 25 60 130 P N 59526447 230V PC 0017NIB 50Hz IP 44 TF 110 Class H...

Страница 29: ...ge 0 27 26 169 28 15 14 5 41 40 39 38 37 36 35 Re 1 Re 2 Re 3 Re 4 Re 5 Re 6 Re 7 29 230 V 12 V B1 C1 34 Brun Bl Svart VR1 C2 C3 F3 F1 F2 C4 L2 L1 5 2 1 3 4 P3 P1 P2 1 2 3 4 5 6 7 8 6 0 kW 1 Noll ble...

Страница 30: ...465 93 92 90 91 Skyddsklensp nning 16 Elektrisk matning 25 Dockning 16 A B och C Se Anslutning i Komponentlista Inom punktmarkerat omr de kan r rdragning fr n golv ej ske 70 A free space of 500 mm is...

Страница 31: ...v k v 2 1 bar 3 0 4 LEK FILTER FILTER 6 7 107 145 8 78 9 16 17 18 1 25 31 32 30 41 44 19 27 33 37 38 39 40 42 44 35 73 152 50 80 14 109 53 55 56 58 59 68 11 65 70 103 71 148 150 47 51 85 88 89 96 82...

Страница 32: ...ssories LEK 10 3 107 67 10 3 107 67 8 2 54 28 57 29 72 22 Top cabinet 245 mm Part no 089 424 Top cabinet 345 mm Part no 089 426 Top cabinet 385 535 mm Part no 089 428 Top cabinet A top cabinet is avai...

Страница 33: ...t air Filter type G2 64 Drawing magnet supply air damper 65 Drying filter with tank 66 Air filter supply air Filter type G2 67 Contactor step 2 68 Docking pipe For the Installer 31 Connection Setting...

Страница 34: ...e installed 47 50 dBA Height excl foot 15 40 mm 2 095 mm Width 600 mm Weight 200 kg Volume double jacket 70 litres Supply voltage 230 V 1 phase N Rated output circulation pump 100 W Rated output suppl...

Страница 35: ......

Страница 36: ...LLEMSTAD NB Tel 0168 477722 Fax 0168 476998 E mail info nibenl nl www nibenl nl V lund Varmeteknik Filial af NIBE AB Brog rdsvej 7 6920 Videb k Tel 97 17 20 33 Fax 97 17 29 33 E mail info volundvt dk...

Отзывы: