General
F2120 is equipped with an internal electronic controller
that handles all functions necessary for operation of
the heat pump, e. g. defrosting, stop at max/min tem-
perature, connection of the compressor heater, and
protective functions during operation.
Temperatures, number of starts and run time, are read
off in the indoor module/control module.
The integrated control shows information via status-
LEDs and can be used during servicing.
Under normal operating conditions the home owner
does not need to have access to the controller.
F2120 communicates with the NIBE indoor module/con-
trol module, which means that all settings and meas-
urement values from F2120 are adjusted and read off
on the indoor module/control module.
LED status
The base board (AA2) has six status LEDs for easy con-
trol and fault tracing.
Explanation
State
LED
Control board without
power
Not lit
PWR
(green)
Control board power on
Continuous
light
CPU without power
Not lit
CPU
CPU running
Flashes
(green)
CPU running incorrectly
Continuous
light
No communication with in-
door module/control mod-
ule
Not lit
EXT COMM
(green)
Communication with in-
door module/control mod-
ule
Flashes
No communication with in-
verter
Not lit
INT COMM
(green)
Communication with invert-
er
Flashes
No defrosting or protection
active
Not lit
DEFROST
(green)
Some protection is active
Flashes
Defrosting in progress
Continuous
light
No errors
Not lit
ERROR
(red)
B-alarm, active
Flashes
A-alarm, active
Continuous
light
Relay in de-energised posi-
tion
Not lit
K1, K2, K3,
K4, K5
Relay engaged
Continuous
light
No function
N-RELAY
Explanation
State
LED
No function
COMPR. ON
Master control
To control F2120, a NIBE indoor module/control mod-
ule is required, which calls upon F2120 according to
demand. All settings for F2120 are made via the indoor
module/control module. It also shows the status and
sensor values from F2120.
Unit
Paramet-
er space
Value
Description
°C
4 – 14
4
Cut-out value activation
passive defrosting
°C
-5 – 5
-3
Start temperature BT16 to
calculate index
(1 / 0)
Yes / No
No
Permit fan de-icing
(1 / 0)
Yes / No
No
Permit silent mode
(1 / 0)
Yes / No
No
Permit defrost more often
33
Chapter 7 |
Control - Introduction
NIBE™ F2120
7 Control - Introduction
Содержание F2120-12
Страница 1: ...Installer manual LEK NIBE F2120 8 12 16 20 Air water heat pump IHB GB 1621 1 331385...
Страница 2: ......
Страница 15: ...Removing the side cover LEK 15 Chapter 2 Delivery and handling NIBE F2120...
Страница 22: ...Installing flex hoses LEK Data Serie nr Art nr 711453 OUT IN XL1 XL2 NIBE F2120 Chapter 4 Pipe connections 22...
Страница 55: ...Electrical circuit diagram 1x230V 55 Chapter 10 Technical data NIBE F2120...
Страница 56: ...NIBE F2120 Chapter 10 Technical data 56...
Страница 57: ...57 Chapter 10 Technical data NIBE F2120...
Страница 58: ...NIBE F2120 Chapter 10 Technical data 58...
Страница 59: ...3x400V 59 Chapter 10 Technical data NIBE F2120...
Страница 60: ...NIBE F2120 Chapter 10 Technical data 60...
Страница 61: ...61 Chapter 10 Technical data NIBE F2120...
Страница 62: ...NIBE F2120 Chapter 10 Technical data 62...
Страница 64: ......
Страница 65: ......
Страница 66: ......
Страница 67: ......