Sound pressure levels
F2040 is usually placed next to a house wall, which
gives a directed sound distribution that should be
considered. Accordingly, you should always attempt
when positioning to choose the side that faces the least
sound sensitive neighbouring area.
The sound pressure levels are further affected by walls,
bricks, differences in ground level, etc and should
therefore only be seen as guide values.
F2040 adjusts the fan speed depending on the ambient
temperature and evaporation temperature.
2 m
6 m
10 m
2 m
LEK
F2040-16
F2040-12
F2040-8
Air-water heat pump
61
57
54
L
W
(A)
Sound power level* According to EN12102 at 7/45 (nominal)
47
43
40
dB(A)
Sound pressure level at 2 m free standing.*
37.5
33.5
30.5
dB(A)
Sound pressure level at 6 m free standing.*
33
29
26
dB(A)
Sound pressure level at 10 m free standing.*
* Free space.
45
Chapter 11 |
Technical data
NIBE™ F2040
Содержание F2040 Series
Страница 1: ...Installer manual LEK LEK LEK NIBE F2040 8 12 16 kW Air water heat pump IHB GB 1512 3 231844...
Страница 2: ......
Страница 55: ...Electrical circuit diagram F2040 8 53 Chapter 11 Technical data NIBE F2040...
Страница 57: ...F2040 12 55 Chapter 11 Technical data NIBE F2040...
Страница 59: ...F2040 16 57 Chapter 11 Technical data NIBE F2040...
Страница 62: ......
Страница 63: ......
Страница 64: ...231844 NIBE AB Sweden Hannabadsv gen 5 Box 14 SE 285 21 Markaryd info nibe se www nibe eu...