Addressing via cascade connection
On the communication board (AA23-S3), the communic-
ation address is selected for F2040 to the control module.
The default address for F2040 is
1
. In a cascade connec-
tion, all F2040 must have a unique address. The address
is coded in binary.
S3:3
S3:2
S3:1
Address
OFF
OFF
OFF
1
OFF
OFF
On
2
OFF
On
OFF
3
OFF
On
On
4
On
OFF
OFF
5
On
OFF
On
6
On
On
OFF
7
On
On
On
8
F2040
Chapter 5 |
Electrical connections
38