Day:
Select which day or days of the week the schedule is to apply to here. To
remove the scheduling for a particular day, the time for that day must be reset
by setting the start time to the same as the stop time. If the line "all" is used, all
days in the period are set for these times.
Time period:
The start and stop time for the selected day for scheduling are
selected here.
Adjustment:
See relevant sub menu.
Conflict:
If two settings conflict with each other a red exclamation mark is dis-
played.
TIP
If you wish to set similar scheduling for every day of the week start
by filling in “all” and then changing the desired days.
TIP
Set the stop time earlier than the start time so that the period extends
beyond midnight. Scheduling then stops at the set stop time the day
after.
Scheduling always starts on the date that the start time is set for.
HEATING
SCHEDULING HEATING
1.3.1
activated
schedule 2
system
schedule 3
schedule 1
all
mon
tues
wed
thur
fri
sat
sun
21:30 - 06:00
20.5°
Time period
Adjusting
Day
Activated
Schedule
System
Conflict
Increases or decreases in the accommoda-
tion temperature can be scheduled here
for up to three time periods per day. If a
room sensor is installed and activated the
desired room temperature (°C) is set during
the time period. Without an activated room
sensor the desired change is set (of setting
in menu 1.1). One step is usually enough
to change the room temperature by one
degree, but in some cases several steps
may be required.
Adjusting:
How much the heating curve
is to be offset in relation to menu 1.1 during
scheduling is set here. If the rooms sensor is installed the desired room temper-
ature is set in °C.
Menu
1.3.1
NIBE F1255PC
BE
Chapter 3 | F1255PC BE – at your service