approx. 60 °C
Electrical installation
Thermostat/
temperature limiter (5)
Immersion heater (6)
Electrical circuit diagram
Installing a thermostat
A setting of 60 °C (max about 80 °C) is recommended
for the best operating conditions.
Electrical installation
The water heater is connected to an earthed socket
power cord for 1 phase installation (1 kW).
1-phase installation provides the best service life for the
immersion heater.
If the power cable is damaged, replacement must be
carried out under the supervision of a qualified electri-
cian.
The lowest point of the power cord should be below the
power socket when you connect the hot water heater to
the socket. This prevents any drops of water from being
led into the socket.
If 3 kW is required hot water heater is connected with
fixed installation (2x400V). At fixed installation the wa-
ter heater is preceded by an isolator (at least with signal
lamp) with at least 3 mm breaker gap. Existing connec-
tion cable can be used if one cuts off the plug.
Electrical installation and service must be
carried out under the supervision of a qual-
ified electrician.