Preparations
NOTE
The routing of electrical wiring between the air
treatment and water heater units must be car-
ried out according to the applicable regulations.
NOTE
Drain F730/F750 of water if it was previously
installed. There may be some hot water when
draining, risk of scalding.
1.
Install the bracket BAU 10 for the air treatment unit.
The air treatment unit must be positioned no more
than 80 cm from the water heater unit.
TIP
See the accessory’s Installer Manual for
more detailed instructions.
2.
Shut off the heat pump and turn off the current on
the safety breaker.
3.
Open the heat pump front covers.
4.
Remove the insulation at the immersion heater.
5.
Remove the actuator for the reversing valve for the
climate control system/water heater (QN10).
6.
Remove the top insulation.
TIP
See the heat pump installer handbook for
more detailed instructions.
Dismantling
1.
Disconnect the wiring between the air treatment
section and the water heater section.
2.
Disconnect the condensation hose from the air
treatment section and from the overflow cup.
3.
Disconnect the pipe connections to the flow and
return lines.
TIP
Lift the air treatment section slightly at the
front edge so that it is easier to access the
pipe connections. The air treatment section
is secured at the front edge of the heat
pump with two screws.
DKI 10 | GB
10
Содержание DKI 10
Страница 2: ......
Страница 8: ...Den f rdiga installationen Bilden visar F750 DKI 10 SE 8...
Страница 23: ...Valmis asennus Kuvassa n kyy F750 23 DKI 10 FI...
Страница 24: ...DKI 10 FI 24...
Страница 25: ......
Страница 26: ......
Страница 27: ......