Knockout
Installation
Combustion air supply
Supply of combustion must be provided. Combustion air can be
drawn directly via a duct from outside, or indirectly via a vent in
the outer wall of the room where the stove is placed. The amount
of combustion air that is used for combustion is approx. 25 m
3
/h.
Some installation alternatives are shown below. The connection
sleeve on the stove has an external diameter of Ø100 mm.
In warm spaces, the duct should be insulated to prevent
condensation using 30 mm mineral wool covered with a vapour
barrier (aluminium tape). It is important that the lead-in,
between the pipe and the wall (or floor), is sealed using jointing
compound.
A 1-metre combustion-air tube insulated to prevent
condensation is available as an optional extra.
Make sure that the installation complies with national and
regional regulations. The installation must be approved by an
authorised inspector.