System solution
AMS 10 is intended for installation with NIBE SPLIT
Box HBS 05 and indoor module (VVM) or control
module (SMO) for a complete system solution.
Safety information
This manual describes installation and service procedures
for implementation by specialists.
The manual must be left with the customer.
This appliance can be used by children
aged from 8 years and above and per-
sons with reduced physical, sensory or
mental capabilities or lack of experience
and knowledge if they have been given
supervision or instruction concerning use
of the appliance in a safe way and under-
stand the hazards involved. The product
is intended for use by experts or trained
users in shops, hotels, light industry,
farming and similar environments.
Children must be instructed/supervised
to ensure that they do not play with the
appliance.
Do not allow children to clean or main-
tain the appliance unsupervised.
This is an original manual. It may not be
translated without the approval of NIBE.
Rights to make any design or technical
modifications are reserved.
©NIBE 2017.
Symbols
NOTE
This symbol indicates danger to person or ma-
chine .
Caution
This symbol indicates important information
about what you should observe when maintain-
ing your installation.
TIP
This symbol indicates tips on how to facilitate
using the product.
Marking
The CE mark is obligatory for most products sold
in the EU, regardless of where they are made.
CE
Classification of enclosure of electro-technical
equipment.
IP21
Danger to person or machine.
!
Read the User Manual.
Safety precautions
Caution
Install the system in full accordance with this installation
manual.
Incorrect installation can cause bursts, personal injury, water leaks,
refrigerant leaks, electric shocks and fire.
Pay attention to the measurement values before working on
the cooling system, especially when servicing in small rooms,
so that the limit for the refrigerant’s concentration is not ex-
ceeded.
Consult an expert to interpret the measurement values. If the refri-
gerant concentration exceeds the limit, there may be a shortage
of oxygen in the event of any leak, which can cause serious injury.
Use original accessories and the stated components for the
installation.
If parts other than those stated by us are used, water leaks, electric
shocks, fire and personal injury may occur as the unit may not work
properly.
Ventilate the working area well – refrigerant leakage may occur
during service work.
If the refrigerant comes into contact with naked flames, poisonous
gas is created.
Install the unit in a location with good support.
Unsuitable installation locations can cause the unit to fall and cause
material damage and personal injury. Installation without sufficient
support can also cause vibrations and noise.
Ensure that the unit is stable when installed, so that it can
withstand earthquakes and strong winds.
Unsuitable installation locations can cause the unit to fall and cause
material damage and personal injury.
The electrical installation must be carried out by a qualified
electrician and the system must be connected as a separate
circuit.
Power supply with insufficient capacity and incorrect function can
cause electric shocks and fire.
Use the stated cables for the electrical connection, tighten the
cables securely in the terminal blocks and relieve the wiring
correctly to prevent overloading the terminal blocks.
Loose connections or cable mountings can cause abnormal heat
production or fire.
Check, after completed installation or service, that no refriger-
ant leaks from the system in gas form.
If refrigerant gas leaks into the house and comes into contact with
an aerotemp, an oven or other hot surface, poisonous gases are
produced.
Switch off the compressor before opening/breaching the refri-
gerant circuit.
If the refrigerant circuit is breached /opened whilst the compressor
is running, air can enter the process circuit. This can cause unusually
high pressure in the process circuit, which can cause bursts and
personal injury.
Switch off the power supply in the event of a service or inspec-
tion.
AMS 10
Chapter 1 |
Important information
4
1 Important information
Содержание AMS 10-12
Страница 2: ......
Страница 12: ...Removing the covers AMS 10 6 LEK LEK LEK AMS 10 8 LEK LEK AMS 10 12 AMS 10 Chapter 2 Delivery and handling 12 ...
Страница 13: ...LEK LEK AMS 10 16 13 Chapter 2 Delivery and handling AMS 10 ...
Страница 28: ...LEK Incoming supply LEK LEK Cable gland AMS 10 Chapter 5 Electrical connections 28 ...
Страница 58: ...AMS 10 16 POWER SOURCE 1 230V 230V 50Hz AMS 10 Chapter 11 Technical data 58 ...
Страница 61: ......
Страница 62: ......