![Nibe ACS 310 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/nibe/acs-310/acs-310_installer-manual_1685965011.webp)
English
General
ACS 310 is an accessory that makes it possible for
VVM 225/VVM 310/VVM 320/VVM 325 to control pro-
duction of cooling.
The cooling system supplies cooling from the heat pump
using a circulation pump via a reversing valve.
For the installation to work the cooling system must flow
freely, for example using a volume vessel for cooling.
Operating mode cooling is activated by the temperature
of the outdoor sensor and any room temperature
sensors, room units or separate room sensors for cooling
(if two different rooms are to be heated respectively
cooled at the same time for example.)
When cooling is required the cooling reversing valve and
the circulation pump are activated. Cooling production
regulates according to the cooling sensor and a cooling
set point value that is determined by the selected cooling
curve. Degree minutes are calculated in response to the
value on the external temperature sensor for cooling
out and the cooling set point value.
Compatible products
Caution
In order for the accessory to work, a NIBE
air/water heat pump must be connected to the
system.
■
VVM 225
■
VVM 310
■
VVM 320
■
VVM 325
Contents
Circulation pump
1 x
PWM cable for circulation pump
1 x
Power cable to circulation pump
1 x
Ball valves with union nut
2 x
Flat gaskets
2 x
Cable ties
2 x
Actuator reversing valve
1 x
Adapter kit, actuator
1 x
Shuttle valve
1 x
Unit box
1 x
Heating pipe paste
1 x
Aluminium tape
1 x
Insulation tape
1 x
Temperature sensor
1 x
Indoor sensor
1 x
Component location unit box (AA25)
LEK
AA5-X4
AA5-S2
AA5-X2
AA5-X9
X1
FA1
AA5-F1
AA5
Electrical components
Miniature circuit breaker, 10 A
FA1
Terminal block, power supply
X1
Accessory card
AA5
Terminal block, sensors and external block-
ing
AA5-X2
Terminal block, communication
AA5-X4
Terminal block, circulation pump, mixing
valve and auxiliary relay
AA5-X9
DIP switch
AA5-S2
Fine wire fuse, T4AH250V
AA5-F1
Designations in component locations according to
standard IEC 81346.
11