GB
16
!
The minimum distance in front of
the stove opening to combustible
parts of the building or interior
decoration must be at least 1 m.
The dimension diagrams only
show the minimum permitted
installation distances for the
stove. When connecting to a steel
flue, also note the safety distance
requirements of the flue. The
safety distance between an un-
insulated flue and a combustible
part of the building should be at
least 450 mm.
Installation distances
WHEN INSTALLING TURNTABLE (OPTION)
the follow-
ing installation distances do not apply.
See the separate turntable installation instructions.
A = height from floor to chimney
connection upwards
B = height from floor to c/c chimney
connection rear
C = height from floor to air inlet
D = height from floor to lower edge
of hatch
A separate glass hearth
plate (accessory)
increases the connection
height to the chimney by
10 mm.
Permitted area for
combustible parts
of the building
* If the stove is placed on a hearth plate made of glass for example (accessory), the height from the floor is affected by a distance corresponding to the thickness of the hearth plate, for a free standing
glass hearth plate this is 10 mm.
** To prevent discolouration of painted non-flammable walls we recommend that the same side distance as to combustible walls is used.
INSTALLATION AGAINST COMBUSTIBLE WALLS
INSTALLATION AGAINST FIREWALLS
1650
540
2400*
D 627
92
219
Combustible roof
140
110
B 1338*
A 1465*
C 649
40
495
Air inlet Ø67
Ø150
800
645
315
100
Combustible wall
650
730
595
265
50
650
Fire-retardant wall
of brick or concrete
1100
520
192
50
250**
900
Fire-retardant wall
of brick or concrete
800
528
600
600
242
100
Combustible wall
C690 / C690G Style
Содержание 690:1 Style
Страница 1: ...C690 Style C690G Style www contura eu ...
Страница 34: ...SE EX 34 2 1 ...
Страница 35: ...SE EX 35 x0 5 5 4 3 ...
Страница 36: ...SE EX 36 7 x2 18 mm 6 ...
Страница 39: ...SE EX 39 1 3 4 2 ...
Страница 40: ...SE EX 40 1 1 2 2 2 4 3 1 ...
Страница 43: ...SE EX 43 4 5 3 6 ...
Страница 44: ...811317 IAV SE EX C690 C690G Style 1 2017 06 19 NIBE AB Box 134 285 23 Markaryd Sweden www contura eu ...