Installing the TB-414X

Complete the following steps to install the TB-414X with a PXIe-414

x

 and prepare signal

connections.

Before you begin, install the PXIe-414

x

 in a chassis and ensure that all signals are

disconnected from the PXIe-414

x

 if you have not already done so. Refer to the getting started

guide for your module at 

http://www.ni.com/manuals

 for installation instructions.

Note

 

Maintaining low leakage performance of the SMU and TB-414X requires

careful selection and termination of the external wiring to ensure guarding of the HI
and HI Sense signals and to minimize negative effects from wiring insulation
materials and contaminants. The SHDB25F-DB25F-LL cable accessory has been
designed with these considerations in mind and utilizes the TB-414X, allowing for
one end to be easily reterminated into an alternate connector, if needed.

Note

 

NI recommends wearing clean gloves during assembly to avoid

contamination from residues or other debris.

1.

Prepare the wires by stripping the insulation 5 mm to 6 mm (0.197 in. to 0.236 in.) from
one end of all wires.

Use signal wires with a wire gauge of 24 to 18 AWG.

2.

Disassemble the TB-414X.
a)

Unscrew the four screws on the top of the TB-414X to remove the top cover.

b)

Unscrew the two screws securing the strain relief to remove the strain relief.

TB-414X User Guide 

  | 

© National Instruments Corporation

  | 

3

Содержание TB-414X

Страница 1: ...nstalling and configuring your system Caution Observe all instructions and cautions in the user documentation Using the product in a manner not specified can damage the product and compromise the buil...

Страница 2: ...when you see this icon printed on the model Cautionary statements are localized into French for compliance with Canadian requirements Getting Started with the TB 414X Kit Contents and Other Equipment...

Страница 3: ...ze negative effects from wiring insulation materials and contaminants The SHDB25F DB25F LL cable accessory has been designed with these considerations in mind and utilizes the TB 414X allowing for one...

Страница 4: ...the stripped end of the wires into the appropriate terminals and tighten the screws of the screw terminals to a torque of 0 5 Nm 4 lb in Refer to the following pinout signal information and PXIe 414x...

Страница 5: ...H 1 C H 2 Table 1 TB 414X Signals and DB25 Pin Map Screw Terminal DB25 Connector Pin LO Connector CH 0 LO 16 CH 0 LO S 3 CH 1 LO 19 CH 1 LO S 6 CH 2 LO 22 CH 2 LO S 9 CH 3 LO 25 CH 3 LO S 12 CH S GND...

Страница 6: ...he strain relief upward If you are connecting only a few wires assemble the strain relief downward for greater retention Figure 3 TB 414X Strain Relief 1 2 1 Strain Relief Up 2 Strain Relief Down b In...

Страница 7: ...ations These specifications apply to the TB 414X for use with the PXIe 414x The PXIe 414x is a 4 Channel SMU Refer to the module specifications at ni com manuals for more information Definitions Warra...

Страница 8: ...nel at the DUT end of the cable must ensure that LO path wiring resistances are matched within 20 to prevent the LO terminal of one channel from carrying a significant portion of another channel s LO...

Страница 9: ...ements of voltages from specially protected secondary circuits Such voltage measurements include signal levels special equipment limited energy parts of equipment circuits powered by regulated low vol...

Страница 10: ...ronmental Guidelines Notice This model is intended for use in indoor applications only Environmental Characteristics Temperature and Humidity Temperature Operating 0 C to 55 C6 Storage 40 C to 71 C 6...

Страница 11: ...NI customers For additional environmental information refer to the Commitment to the Environment web page at ni com environment This page contains the environmental regulations and directives with whi...

Страница 12: ...RMA by NI does not constitute export authorization The user must comply with all applicable export laws prior to exporting or re exporting this product See ni com legal export compliance for more inf...

Страница 13: ...f help such as tutorials and examples Visit ni com services to learn about NI service offerings such as calibration options repair and replacement Visit ni com register to register your NI product Pro...

Страница 14: ...LAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and how...

Отзывы: