NI SCC-RLY01 Скачать руководство пользователя страница 3

©

 National Instruments Corporation

3

SCC-RLY01 Relay Module User Guide

Documentation for your hardware

Documentation for your software

Tools

1/8 in. flathead screwdriver

Numbers 1 and 2 Phillips screwdrivers

Wire insulation stripper

You can download NI documents from 

ni.com/manuals

. To download 

the latest version of NI-DAQ, click 

Download Software

 at

ni.com

.

Note

Configuring the SCC system using Measurement & Automation Explorer (MAX) is 

not supported on the Macintosh operating system.

Device Specific Information

Note

For general SCC module installation and signal connection information, and 

information about the SCC-68 or SC-2345 carrier, refer to the 

SCC Quick Start Guide

available for download at 

ni.com/manuals

.

Installing the Module

Caution

Refer to the 

Read Me First: Safety and Radio-Frequency Interference

 document 

before removing equipment covers or connecting/disconnecting any signal wires.

Plug the SCC-RLY01 into any DIO socket J(

X

+

9), where 

X

 is 0 to 7, on the 

SC-2345 or into any of the four slots that correspond to P0.0 to P0.3, on the 
SCC-68.

Connecting the Input Signals

Note

The signal names have changed. Refer to 

ni.com/info

 and enter 

rdtntg

 

to confirm the signal names.

Each screw terminal is labeled by pin number <1..3>. Pin 1 is the 
NC terminal, pin 2 is the COM terminal, and pin 3 is the NO terminal.

The SCC-RLY01 contains one SPDT relay controlled by the digital line of 
an E/M Series DAQ device P0. line 

X

. The value of 

X

 is determined by the 

number of the DIO socket, J(

X

+

9) on the SC-2345 or SCC Mod (

X

 + 1) on 

the SCC-68, where you plug in the SCC-RLY01. Figure 1 shows a circuit 
diagram of the SCC-RLY01.

Содержание SCC-RLY01

Страница 1: ...nt a range of values associated with a bit or signal name for example P0 3 0 The symbol leads you through nested menu items and dialog box options to a final action The sequence File Page Setup Option...

Страница 2: ...ries programs subprograms subroutines device names functions operations variables filenames and extensions SC 2345 SC 2345 refers to both the SC 2345 connector block and SC 2345 with configurable conn...

Страница 3: ...manuals Installing the Module Caution Refer to the Read Me First Safety and Radio Frequency Interference document before removing equipment covers or connecting disconnecting any signal wires Plug the...

Страница 4: ...kshell Figure 2 High Voltage Backshell For information about how to configure the SCC RLY01 module with NI DAQmx refer to the SCC Quick Start Guide Specifications These ratings are typical at 25 C unl...

Страница 5: ...e Signal bandwidth DC to 400 Hz Contact resistance 30 m max Switching time Operate time NC to NO 5 ms 10 ms max Release time NO to NC 4 ms 5 ms max 1 Maximum operating speed 30 cps at rated load Conta...

Страница 6: ...ion to signals in Measurement Category II III or IV Do not connect to MAINS When used with an SCC 68 Channel to earth inputs 300 VDC Measurement Category II1 Caution Do not use for connection to signa...

Страница 7: ...ts Minimum Immunity EN 55011 Emissions Group 1 Class A CE C Tick ICES and FCC Part 15 Emissions Class A Note For EMC compliance operate this device according to product documentation CE Compliance Thi...

Страница 8: ...on the bottom of the module Figure 4 SCC Module Bottom View Table 1 lists the signal connection corresponding to each pin GND is the reference for the 5 V supply 1 Pin 1 2 Pin 2 3 PWB Key 4 Pin 19 5 P...

Страница 9: ...any names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products refer to the appropriate location Help Patents in your softwar...

Отзывы: