© National Instruments
|
3-17
Front Panel Features
The NI PXIe-8135 has the following front-panel features:
•
A system reset pushbutton (press the button to generate a reset to the controller)
•
Two front panel LEDs that show PC status
–
The
PWR OK/FAULT
LED indicates the status of the controller. The LED will
indicate one of the following states:
•
Green ON steady—PXI Express and onboard power is on and within regulation
limits.
•
Green BLINKING—The controller has entered the soft off state and is safe to
power down.
•
OFF—The controller is powered off.
•
Red BLINKING—The controller detected a power rail fault when trying to boot.
•
Red Solid—The controller detected a thermal fault and has shut down to protect
the system.
–
The
DRIVE
LED indicates when an access to the internal hard disk is occurring.
–
The
USER1
LED is a bi-color green/yellow LED. You can define the USER1 LED to
meet the needs of your LabVIEW application.
–
The
USER2
LED is a bi-color green/yellow LED. You can define the USER2 LED to
meet the needs of your LabVIEW application.
Data Storage
The NI PXIe-8135 has the following data storage features:
•
Internal Serial ATA hard drive
–
250 GB or larger 2.5 in. notebook hard drive
–
Supports Native Command Queuing
–
Supports transfer rates up to 600 MB/s
•
Removable Serial ATA hard drive (Removable hard drive variant only)
–
250 GB or larger 2.5 in. notebook hard drive
–
Supports Native Command Queuing
–
Supports transfer rates up to 300 MB/s
•
USB storage support—USB CD/DVD-ROM, mass storage device, or floppy drive