![NI FieldPoint cFP-AIO-600 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/ni/fieldpoint-cfp-aio-600/fieldpoint-cfp-aio-600_operating-instructions-manual_1685613015.webp)
FP-AIO-600 and cFP-AIO-600
14
ni.com
Current Inputs
Effective resolution ........................... 11.3 bits
Input impedance................................ 105
Overcurrent protection
100 mA
Overvoltage protection
10 V
Signal input bandwidth (–3 dB)........ 350 Hz
Current input accuracy by current input range
0–18 V
0.04%;
0.10%
0.16%;
0.13%
0–36 V
0.04%;
0.09%
0.16%;
0.10%
6 V
0.04%;
0.12%
0.19%;
0.17%
12 V
0.04%;
0.10%
0.19%;
0.12%
18 V
0.04%;
0.09%
0.19%;
0.11%
36 V
0.04%;
0.08%
0.19%;
0.09%
Current Input
Range (with
Overranging)
Accuracy
at 15 to 35
°
C
(% of Reading;
% of Full Scale)
Accuracy
at – 40 to 70
°
C
(% of Reading;
% of Full Scale)
0–24 mA
0.07%;
0.08%
0.29%;
0.08%
3.5–24 mA
0.07%;
0.10%
0.29%;
0.10%
24 mA
0.07%;
0.08%
0.32%;
0.08%
Voltage Input
Range (with
Overranging)
Accuracy
at 15 to 35
°
C
(% of Reading;
% of Full Scale)
Accuracy
at – 40 to 70
°
C
(% of Reading;
% of Full Scale)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com