GPIB Hardware Installation Guide and Specifications
|
© National Instruments
|
29
Environment
Operating ambient temperature
0 °C to 55 °C
(Tested in accordance with IEC 60068-2-1 and
IEC 60068-2-2.)
Operating relative humidity
10% to 90%, noncondensing
(Tested in accordance with IEC 60068-2-56.)
Storage ambient temperature
-20 °C to 70 °C
(Tested in accordance with IEC 60068-2-1 and
IEC 60068-2-2.)
Storage relative humidity
5% to 95%, noncondensing
(Tested in accordance with IEC 60068-2-56.)
PXI-8232
Performance
GPIB
3-wire
up to 1536 kbytes/s
HS488
up to 7885 kbytes/s
Ethernet interface
10Base-T
up to 10 Mbit/s
100Base-TX
up to 100 Mbit/s
1000Base-T
up to 1000 Mbit/s
Power Requirements
+5 V
917 mA, Typical
1500 mA, Maximum
Physical Characteristics
Dimensions
10.0 cm × 16.0 cm (3.9 in. × 6.3 in.), 3U
Connector
GPIB
IEEE 488 24-pin connector
Ethernet
RJ-45 with integrated LEDs