How to Replace the Filter

5

 Insert the new filter into the compartment. 

-Remove the plastic caps covering both ends of the new filter.

-Seat the large opening on the bottom of the filter cartridge onto the base.

- Push the filter down and into the housing compartment ensuring the 
   opening at the top of the filter is seated properly into the fitting at the 
   top of the housing

Check for leaks by running water through your ionizer before replacing the 
housing cover.

Flush out the GAC carbon dust.
- The water will initially come out discolored (light to charcoal 
   gray) due to carbon particulates in the new filter. 
   This is not harmful and is typical of all GAC filters. 
   Allow the water to flow for 2-3 minutes in the "Purified" mode 
   and this will flush all the carbon dust.

6

7

Immediately after filter replacement, the water will come 
out black and unclear due to the activated carbon particulates 
in the new filter but will become clear momentarily. 
(It is not harmful.)

Reset
Button

Reset the filter life indicator.

- With your ionizer in standby mode (water not runni ng through the ionizer)  
   press the "Reset" button located at the top of the filter housing compartment 
   for 3~5 seconds.

- Replace the filter housing cover.

4

Remove the expired filter. 

-Taking hold of the filter securely with you right hand, press the

  filter firmly down against the spring loaded mechnism to disengage

  the top of the filter and then lean the filter out toward you and lift up

  to remove it.

-The upper part of the filter is separated from housing by pressing

  firmly down. Once you have engaged the spring loaded mechanism,

  you can then easily remove the filter from the main body by

  leaning the filter out toward you and life up to remove it.

Filter

WARNING INDICATORS 

1) LOW PRESSURE - The Low Pressure Warning indicator will flicker 
    when water flow or pressure into the machine is weak. 
    Increase the water flow to resolve this condition. 
2) HOT WATER - The Hot Water Warning indicator will flicker when you 
    have inadvertently run hot water into the machine. 
    Switch back to cold water immediately to resolve this condition. 
    Allow the cold water to flow for about a minute.   

Содержание X-BLUE

Страница 1: ...IZER NEXUS CO LTD Second floor 163 12 DOD NG DONG A WONMI GU BUCHON SI KYUNG GI DO KOREA 82 2 898 7005 Warning Incorrect installation and or operation could void your valuable warranty Please protect...

Страница 2: ...occurs do not make a repair by yourself Contact the place of purchase or A S center Electrical power precautions If your ionizer becomes submerged in water unplug the power cord from the wall BEFORE r...

Страница 3: ...ic shock Do not attempt to repair or service the unit yourself Contact your dealer Attempting to do so will void your valuable warranty Make sure to use your ionizer only with potable water which is s...

Страница 4: ...f immediately Make sure to keep the pH reagent liquid tightly closed and out of the reach of children Some helpful tips For storing your alkaline water glass or ceramic is best Always try and keep you...

Страница 5: ...rd Filter cover Body Function display panel Flexible stainless steel alkaline water outlet Front Back Flow Control Valve This controls the flow rate of water through your ionizer Tip This adjustment h...

Страница 6: ...An Alkaline symbol shows which level of alkaline water is selected ALKALINE water button Used to select alkaline water and the desired level 1 4 PURIFIED water button Used to select purified water ACI...

Страница 7: ...ort labelled ACIDIC WATER OUTLET on the bottom of the ionizer First slide a squeeze clamp over the end of the hose Then attach the gray hose by simply pushing it firmly over the white plastic port Soa...

Страница 8: ...e and adjust faster or slower as necessary to achieve optimum results TO SELECT ALKALINE WATER 1 With water running through the ionizer 2 Depress the ALKALINE button to select the desired setting from...

Страница 9: ...nge accordingly TO SELECT ACIDIC WATER TO SELECT PURIFIED WATER With water flowing through the machine depress the PURIFIED button The purified water runs through the Biostone filter but does not rece...

Страница 10: ...er This water is simply cleaned of impurities by the advanced filtration system You can use it both as drinking water and to take medications with Some uses for the different levels of Acidic Water Pr...

Страница 11: ...e vomiting seek medical help Important Note Water quality and mineral content vary greatly in different localities and will directly impact performance of your ionizer with respect to pH ALKALINE WATE...

Страница 12: ...eset Button Reset the filter life indicator With your ionizer in standby mode water not runni ng through the ionizer press the Reset button located at the top of the filter housing compartment for 3 5...

Страница 13: ...rmaline in ceramic form so you get FIR on tap Non woven fabric filter Filters out sediment and particulate Granular Activated Carbon GAC The workhorse of the filtration media GAC is especially effecti...

Страница 14: ...pressure in your household plumbing The input hose is bent kinked or otherwise restricted Replace your filter Clean Pre filter Ensure water supply valves are fully open The water pressure in house ma...

Страница 15: ......

Страница 16: ...30 31 MEMO MEMO...

Отзывы: