C-4.4 Installation Instructions
Rev 1; 6-25-07
6
Figure 1 C-4.4 Front Panel
FEATURES
C-4.4 CONTROLLER FRONT PANEL
1. Zone Status/Programming Indicators –
Four multicolor/multifunction LED’s indicate the following
modes:
•
Power Up –
During power up, the C-4.4 will enter an initialization mode where it will try to make
contact with the attached keypads. The LEDs give an indication of this process on a per zone
basis by illuminating green while the keypad for that zone is tested. If the keypad is contacted
successfully, the LED for that zone will remain green, and the LED for the next zone will
illuminate as it is tested. If there is a failure to communicate with a particular keypad, because
there is no keypad connected or due to a wiring error, the LED for that zone will turn red for the
duration of the initialization sequence, after which all LEDs will turn off.
•
Zone Status –
Solid green indicates an active zone. (Zone ON)
•
Source IR Output –
When an IR command is output from the C-4.4 the LED for the zone
initiating the command will flash green to indicate that the code was sent. When a button is
pressed that does not have a command programmed to it, the LED will flash red.
•
Programming Status –
LEDs will change from green to red to orange with varying modes of
scrolling, flickering, flashing and solid states indicating different programming modes and status.
See Section:
Programming
for additional information.
2. IR Port –
IR sensor used for learning IR controlled source commands.
Figure 2 C-4.4 Rear Panel