background image

NPSM481 Series Instruction Manual

NPSM481 Series V3.0

www.nextys.com

Page 2/5

DECLARATION OF CONFORMITY

NEXTYS SA.

Via Luserte Sud 6, 6572 Quartino - Switzerland

Phone: +41-(0)91 840 14 46 / 840 14 48; Fax: +41-(0)91 840 14 47

E-mail: [email protected]

This Declaration of Conformity is suitable to the European Standard EN45014 "General criteria for supplier’s declaration of conformity".

We declare under our sole responsibility that the device included in this box, has passed all processing inspections and the final test and it is in conformity with the product

requirements, including all reference codes and supply specifications.
ROHS compliance: the product respects the EC requirements related to ROHS substances, according to “Restriction of Hazardous Substances” as per document 2011/65/UE

REACH compliance: the product respects the EC requirements related to REACH SVHC directive (EC) 1907/2006

Note: all the reported information comes from our suppliers, NEXTYS SA. has not run any test to evaluate if the specific elements are present.
All indicated devices are designed according to the latest Reference standards, if not expressly indicated through the official documents or files, they have been tested through

our internal pre-compliance testing. Consult directly on www.nextys.com the reference standards applied to each model.

Code

Description

NPSM481-24

Single phase with integrated PFC switching power supply IN 120 - 240Vac (110 - 345Vdc) / OUT 24Vdc - 20A

NPSM481-24H

Single phase with integrated PFC switching power supply IN 120 - 240Vac (110 - 345Vdc) / OUT 24Vdc - 20A + Increased surge protection

NPSM481-24P

Single phase with integrated PFC switching power supply IN 120 - 240Vac (110 - 345Vdc) / OUT 24Vdc - 20A + ORing circuit

NPSM481-24PH

Single phase with integrated PFC switching power supply IN 120 - 240Vac (110 - 345Vdc) / OUT 24Vdc - 20A + ORing c Increased surge protection

NPSM481-36

Single phase with integrated PFC switching power supply IN 120 - 240Vac (110 - 345Vdc) / OUT 36Vdc - 14A

NPSM481-36H

Single phase with integrated PFC switching power supply IN 120 - 240Vac (110 - 345Vdc) / OUT 36Vdc - 14A + Increased surge protection

NPSM481-36P

Single phase with integrated PFC switching power supply IN 120 - 240Vac (110 - 345Vdc) / OUT 36Vdc - 14A + ORing circuit

NPSM481-36PH

Single phase with integrated PFC switching power supply IN 120 - 240Vac (110 - 345Vdc) / OUT 36Vdc - 14A + ORing c Increased surge protection

NPSM481-48

Single phase with integrated PFC switching power supply IN 120 - 240Vac (110 - 345Vdc) / OUT 48Vdc - 10A

NPSM481-48H

Single phase with integrated PFC switching power supply IN 120 - 240Vac (110 - 345Vdc) / OUT 48Vdc - 10A + Increased surge protection

NPSM481-48P

Single phase with integrated PFC switching power supply IN 120 - 240Vac (110 - 345Vdc) / OUT 48Vdc - 10A + ORing circuit

NPSM481-48PH

Single phase with integrated PFC switching power supply IN 120 - 240Vac (110 - 345Vdc) / OUT 48Vdc - 10A + ORing c Increased surge protection

NPSM481-72

Single phase with integrated PFC switching power supply IN 120 - 240Vac (110 - 345Vdc) / OUT 72Vdc - 6.7A

NPSM481-72H

Single phase with integrated PFC switching power supply IN 120 - 240Vac (110 - 345Vdc) / OUT 72Vdc - 6.7A + Increased surge protection

NPSM481-72P

Single phase with integrated PFC switching power supply IN 120 - 240Vac (110 - 345Vdc) / OUT 72Vdc - 6.7A + ORing circuit

NPSM481-72PH

Single phase with integrated PFC switching power supply IN 120 - 240Vac (110 - 345Vdc) / OUT 72Vdc - 6.7A + ORing c Increased surge protection

Certifications and approvals

IND.CONT.EQ. 4WX9

Reference standards

2014/35/EU

(Low Voltage Directive)

2014/30/EU

(EMC directive)

EN60950-1

(Safety Standards)

UL508

(Certified - IND. CONT. EQ. 4WX9 file no. E356563. Models (-36) and those ending with (H) are not UL certified)

EN61000-6-2

(Generic immunity standard for industrial environments)

- EN61000-4-2

(Electrostatic discharge immunity test)

- EN61000-4-3

(Radiated, radio-frequency, electromagnetic field immunity test)

- EN61000-4-4

(Electrical fast transient/burst immunity test)

- EN61000-4-5

(Surge immunity test)

- EN61000-4-11

(Voltage dips, short interruptions and voltage immunity test)

EN61000-6-3

(Generic emission standard for residential environments)

- EN55011

(CISPR11 - EMC)

- EN61000-3-2

(Limits for harmonics current emissions)

Date:

07.02.2018

Place:

Quartino, Switzerland

The product manager

Marius Ciorica

Содержание NPSM481 Series

Страница 1: ...onamento si verificano guasti o anomalie inviarlo al produttore per il controllo Nextys SA non si assume nessuna responsabilità per qualunque conseguenza derivante dall uso di questo materiale Lisez ces instructions avant l installation conservez ce manuel pour référence future Défaut de se conformer à ces instructions peut affecter les caractéristiques et la sécurité du dispositif de danger et de...

Страница 2: ...ng power supply IN 120 240Vac 110 345Vdc OUT 36Vdc 14A Increased surge protection NPSM481 36P Single phase with integrated PFC switching power supply IN 120 240Vac 110 345Vdc OUT 36Vdc 14A ORing circuit NPSM481 36PH Single phase with integrated PFC switching power supply IN 120 240Vac 110 345Vdc OUT 36Vdc 14A ORing circuit Increased surge protection NPSM481 48 Single phase with integrated PFC swit...

Страница 3: ...eter to a wide range see Fig 1 Check Uout before connecting the power supply to the load With output voltage set to the max value the continuous current x voltage must not exceed the nominal power 8 Parallel connection and redundancy power supplies can be connected in parallel to increase power For paralleling for power set the Ilim jumper to C C algorithm Uout must be set uniformly 100mV on each ...

Страница 4: ...gative DC I earth ground Output Positive DC Negative DC Dry contact NC Dimension W D H mm inch 56 2 20 117 4 60 140 5 51 Distance A B mm inch 20 0 8 100 3 9 Fig 4 Mounting Dismounting Instructions For DIN rail fastening according to IEC 60715 TH35 7 5 15 Mounting as shown in figure with input terminals on lower side with suitable cooling and maintaining a proper distance between adjacent devices a...

Страница 5: ...7 Input connections AC Line DC Line Fig 8 Environment Operating temperature Derating 40 C 70 C 5 95 r H non condensing UL Certified up to 50 C at 120Vac UL Certified up to 60 C at 240Vac Overtemperature protection 7 6W C over 50 C at 120Vac 7 2W C over 60 C at 240Vac Note Data may change without prior notice in order to improve the product Please refer to the latest version of the Instruction Manu...

Отзывы: