background image

CONSIDERATIONS FOR INSTALLATION

Fig. 2

Fig. 1

Fig. 3

Fig. 4

ENGINE WITHOUT CLUTCH

ADAPT THE SYSTEM WITH THE INSTALLATION OF SECURITY SYSTEMS

Ÿ

 The  installation  and  testing  operations  must  be  performed  solely  by  qualified

personnel in order to guarantee the proper and safe operation of the automatic
gate.

Ÿ

 The  company  declines  any  responsibility  for  damage  caused  by  incorrect

installations due to   incompetence and/or negligence.
Also check that the runner on the ground

( Fig. 1)

is not deformed, is perfectly

level  and  that  the  mechanical  stop  is  present  on  opening

(Fig.  2)

in  order  to

prevent the gate from going beyond the upper runners

(Fig. 3)

Mechanical stop

Rounded section

Corner section

Ÿ

 Check the upper runner

(see Fig. 3)

is firm and the gate slides freely.

Ÿ

 Check that the wheels

( Fig. 4)

used are suitable for the type of runner on the

ground

Содержание TOPP Series

Страница 1: ...roughly read this manual that is an integral part of the pack The CE mark conforms to European directive EEC 89 336 92 31 93 68 D L 04 12 1992 N 476 Our products if installed by qualified personnel ca...

Страница 2: ...ES OF COMPONENTS 3 TECHNICAL DATA 3 DIMENSIONS 4 TYPICAL CONNECTION AND CABLE SECTION 4 CONSIDERATIONS FOR INSTALLATION 5 INSTALLATION 6 7 TROUBLESHOOTING 8 SAFETY PRECAUTIONS 11 PACKING CONTENTS 1 GE...

Страница 3: ...supply 230 380Vac Motor current input 2 5 A Motor power 750 W Mechanical unlock for emergency manoeuvre With key Working temperature 25 C 70 C Weight 40 Kg Gear Z20 Protection rating IP 54 Limit swit...

Страница 4: ...IONS TYPICAL CONNECTION AND CABLE SECTION 2X0 75mm2 4X0 75mm2 4X0 75mm2 2X0 75mm2 4X1 5mm2 Line Tree phase Motor 665 mm 190 mm 365 mm 225mm Electronics 4X1 5mm2 6X0 75 38mm 138 mm RX Photocell TX Phot...

Страница 5: ...ines any responsibility for damage caused by incorrect installations due to incompetence and or negligence Also check that the runner on the ground Fig 1 is not deformed is perfectly level and that th...

Страница 6: ...e an excavation Insert the trunking Level and cement the fixing plate Open the front cover remove the casing from the motor by unscrewing the screws present in the lower part of the casing Place the m...

Страница 7: ...n 2 and 3 mm from the motor pinion Fig 3 Fig 3 2 3mm 1 Open the front cover Fig 4 2 Insert the supplied hex wrench 3 Turn clockwise to lock and counterclockwise to unlock Fig 5 Emergency release Conne...

Страница 8: ...cable to appropriate terminal or replace The photocell is not functioning or the beam is interrupted Check the connection remove any obstacle across the beam On giving a command with the remote contro...